03. Technical Specifications

Check the production label for technical specifications. Check voltage and frequency before
use.
Sound pressure measured towards the human ear in dB(A) according to "free field method" at
a distance of 7 meters: 44 dB (A)
04. Assemby / mounting / installation
Mounting, electric connection and start-up may be executed by qualified personnel only
(according to EN 50110-1 and EN 1010-1).
It is the installer's responsibility that the installation and safety instructions are in
accordance with current standards and regulations (according to EN-ISO 13857 and EN
ISO 12100)
Every fan has to be grounded according to the current standard EN 50178.
Connect the fan according to the connection diagram.

04.1. Assembly

Assemble the fan according to the instructions, see FIG IV in the assemby manual.

05. Storage / Transport

Transport and store the fan only in its original packaging.
Storage temperature: –40˚C to +60˚C.
Avoid impacts and unnecessary loads to packaging and/or fan.
In case the packaging is damaged, check for damages on the fan.

06. Start-up

Before connecting the fan to mains power supply, make sure that the specifications on the
production label match the local voltage and frequency. Make sure that the controller is
suitable for the fan or that the fan is suitable for the controller.
VF9258C 10.10.2013
Translation of the Original Manual
Switch off the mains supply before installing the fan.
CAUTION: The fan must ALWAYS be mounted in a stable way before being
taken into operation!
19/34