Operation
menu
3.4.4

Battery protection

menu
menu
CAUTION!
If you stop protective charging manually, battery protection is disabled
until the next time the fuel cell is started. Deep discharge may damage
your battery.
All manuals and user guides at all-guides.com
ok
!
ok
!
ok
!
1.
Press
on the operating panel.
2.
Select "Manual Off" operating mode.
3.
Press [ok] to confirm your selection.
The EFOY fuel cell shuts down gracefully
after you press [ok]. This may take some
time, to ensure that all protective features
are applied.
The EFOY fuel cell has an integrated
battery protection function. This function
prevents deep discharge of the battery
when the "Off" operating mode is selected.
Battery protection is activated
automatically if the battery voltage drops
below 11.2 V for more than 15 minutes.
The "Battery protection" charging mode
ends as soon as voltage reaches 12.8 V.
This function serves only to protect the
battery, and does not charge it.
If you want to switch off the fuel cell after
the battery protection function has started,
press
. The function is re-enabled
automatically when the device is switched
on or is operated in automatic mode.