Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Operation - aquanique GP 3200 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -

Installation and connection

N O T E
If the pump is used as a booster pump, ensure that the max. internal pressure of 6 bar on the pressure side is
not exceeded.
• The pump pressure is added to the pre-pressure.
• Example: Pre-pressure = 1 bar, max. pressure of the pump = 4.5 bar, total pressure = 5.5 bar.
T I P
For permanent installation of the pump, use flexible compression-proof hoses to connect it to the pipe network
to reduce the noise of the pump.
T I P
• Equip the suction line with a pre-filter and non-return valve or foot valve.
• Additionally fasten the suction hose (e.g. by tying it to a wooden stake) to relieve the weight of the hose on
the pump.
• Install the pump in a horizontal and stable position in a dry place.
– For permanent installation of the pump, ensure that a sufficiently large collecting basin can be positioned under-
neath the discharge screw for emptying the pump.
• If possible, install the pump in a higher position than the container/reservoir from which the water is to be pumped. If
this is not possible, a pressure-proof valve must be fitted between the pump and the suction hose.
• Only use vacuum-proof pressure hoses on the pressure and suction side.
 B
• Screw the suction hose and the pressure hose together with the hose connector, hose clip and fitting onto the suction
side (G1) or pressure side (G1) respectively.

Operation

C A U T I O N
Risk of burns due to hot water. Water in the pump may be heated to a high temperature in the event of defec-
tive electronics or lack of water supply on the suction side.
• Disconnect the power plug before carrying out any work on the unit.
• Allow the water in the pump to cool down.
Start-up of the device
It is necessary to fill the pump and expel the air from the suction line before using. It can take several minutes to expel
air from the suction line.
How to proceed:
 C
1. Unscrew the water infill screw.
2. Pour water into the infill opening until it overflows.
3. Screw in the water infill screw again.
4. Open the pressure line if necessary.
5. Insert the power plug into the socket.
6. Switch on the pump.
– The pump starts pumping immediately. The emerging water still contains some air.