Herunterladen Inhalt Inhalt Diese Seite drucken

Jago RMTMS01 Bedienungsanleitung Seite 32

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Dis play
S
t e
h t
e
o c
n
e t
t n
temperature correction
AdJ
It is used to correctthe error,the measured values the sensor . When you set it, the LCD displays the correction
correct the error,
value. After three seconds, the LCD displays the measured value after correction.
T
h
e
p
r e
o i
d
i t -
m
e
PrG
5+2 :Monday to Friday to set the same and Saturday to Sunday to set the same
6+1 :Monday to Saturday to set the same, Sunday is independent
7:Monday to Sunday is same setting value.
A
n
f i t
e r
z e
e
LtP
Low temperature protection, what is suitable for the water system
freezing.
temperature control mode at different
Sensor or temperature control mode
Sen
sensor setting
IN: temperature control mode at different sensor setting OUT: control by floor sensor, only with external sensor
IN : internal control, room sensor
ALL: Dual temperature control, the heater stop when room temperature > setting value or floor temperature > setting value (tOP)
control, the internal room temperature sensor, external sensor overheating protecting
floor-temperature's limited value
External temperature sensor limit
tOP
floor-temperature limited value with ALL mode (Sen)
The sensor is set to ALL, the temperature limit external sensor value
Internal sensor hysteresis
dt0
Built-in temperature sensor hysteresis
External sensor hysteresis
dt1
External temperature sensor hysteresis
B
a
k c
g i l
h
n i t
g
t s
t a
bL
Backlight lighting mode, can be set according to personal preference
status when boot
S
t
t a
s u
t a
e r
p -
o
w
Sat
boot status, off status or continue previous status
Used to control the power state of the boot
deF
Restore factory settings
t
he error and solution of Common system
1. No display
• Power supply system is having problems or power is supplied incorrectly, please check
if the inlet wire is normal.
• If the connection is not right, please wired up as the wiring diagram on the back side.
• The thermostat of the working environment temperature is too low, please note the
thermostat temperature range.
If the temperature is lower than -5 °C, the thermostat cannot normally display.
• Power supply box and the motherboard Coupling is not connected correctly, please
connect correctly.
• Power supply box and the motherboard Coupling is opposite inserted, please mind
the direction
• Power supply box and the motherboard Coupling is broken, please don't overexert.
Coupling length is 6cm,
the installation must be careful. If damaged, no replacement.
DE FR EN
A
d
j ustment ran g e
,setting item
-5 ~ 5
m
o
d
e
5
+
2
O
: n
IN: Built-in
ALL: Dual temperature control
Out : external control, floor sensor
40-80
value
0.5-4
value
value
0.5-5
value
s u
O
: n
OFF :Auto turn off after 5sec
r e
O
F
: F
On: the same as previous,
Restore factory settings
EN
the sensor
/
6
+
1
/
7
E
n
a
b
e l
/
O
F
: F
i D
a s
b
e l
To prevent the pipe at low temperature was
protect
OUT: External
A
w l
a
s y
o
n
boot
o
f f
t s
t a
s u
t a
e
e v
y r
i t
m
e
32
The default value
-2.5
5
+
2
O
F
F
from
IN
ALL : double temperature double
50
1
3
OFF
OFF
To restore the default settings
Inhaltsverzeichnis
loading

Inhaltsverzeichnis