The lamp assembly and electrical installation must be car-
ried out by a qualified electrician.
18 x 18 is equally suitable for direct and indirect lighting.
The two ball joints make the lamp freely movable.
Alternative methods of installation
Version A:
Directly in the wall (masonry, concrete or
plasterboard), using an existing or purpose-
fitted flush-mounting wall fixture (N.B.: the
screws must be set exactly 60 mm apart)
Version B:
Using the canopy base supplied, in conjunction
with an existing electrical outlet
Caution:
Switch off or remove the mains fuse before going
any further. Take care to ascertain the exact position of
the mains cable, so as to avoid drilling into it. Do not
attach the lamp to a damp and/or conductive surface!
Version A - Flush-mounting wall fixture
Preparations A
Loosen the two screws (1) on the wall fixture (2) by about
5 mm. Remove a 12 cm section of the outer covering from
the mains cable (3), then strip about 5 mm from the ends
of the three leads. ①
Detach the square cover (4) with the magnet from the
base plate of the lamp (5).
Assembly A
Hold the base plate with one hand and connect the three
leads to the appropriate contacts in the terminal block (6).
The earth contact is the one in the middle. ②
8
English
Attach the base plate to the wall fixture, with the cable
outlet at the top and the mounting rod pointing down-
wards. ③
Tighten the screws, ensuring that the base plate is properly
centred on the wall fixture. Replace the square cover (4)
by pressing it gently onto the base plate (5) until the
magnet (7) fits into position with an audible click. Adjust
the position of the square cover by turning it so that the
ball joint (8) is fully visible through the aperture (9) in the
centre. ③
Finally, replace the fuse and switch on the light.
Version B - Surface-mounted wall fixture
Preparations B
Using the wall fixture supplied with the lamp as a template
(10), mark and drill two 6 mm-diameter holes (11).
Caution:
Take care to ascertain the exact position of the
mains cable, so as to avoid drilling into it.
Insert the plugs (12) and attach the wall fixture with the
screws. Remove a 12 cm section of the outer covering
from the mains cable (13), then strip about 5 mm from
the ends of the three leads. ④
Assembly B:
Same procedure as for version A. ②-③