Herunterladen Diese Seite drucken

Siemens SIMATIC ET 200eco PN Produktinformation Seite 2

Vorschau ausblenden Andere Handbücher für SIMATIC ET 200eco PN:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Configuration software
STEP 7 (TIA Portal) as of V14
STEP 7 as of V5.5 SP4 or later
STEP 7 as of V5.6 SP1 or later
Software of another manufacturer
Dependencies ET 200eco PN F-DI 8 x 24 VDC, 4xM12 / F-DQ 3 x 24
VDC/2.0A PM, 3xM12 (6ES7146-6FF00-0AB0) as of firmware version
V1.0.0
Re-integration after a channel fault depends on the host used. You can find information on this in the documentation of the
host.
In the TIA Portal, the "IO Tags" tab displays more tags than supported by the F module.
Dependencies for 1oo2 evaluation
In a 1oo2 channel configuration, you must set the following 1oo2 DI channel parameters to the same value:
● Activated check box
● Input filter
● Channel failure acknowledge
● Sensor supply
Siemens AG
Division Digital Factory
Postfach 48 48
90026 NÜRNBERG
GERMANY
Configuring ET 200eco PN Fail-Safe Modules with a GSDML File
A5E46726754-AB, V1.0, 04/2019
2
Information on installation
STEP 7 online help
STEP 7 help
Documentation of the manufacturer
Configuring ET 200eco PN Fail-Safe Modules with a GSDML File
Requirements
S7-FCT V2.0
A5E46726754-AB, V1.0, 04/2019