Explanation of the user interface:
Please note:
Heating mats / heating foils may only be heated at a maximum of 30°C under the laminate!
Please always follow the manufacturer's instructions.

Technical specifications:

Rated voltage:
Switching capacity:
Protection class:
Temperature range:
Switching hysteresis:
External sensor:
Temperature setting:
The control range is between +5° and +40°C. To assist with setting, the thermostat has an LED that lights RED when the heating is
on. When first starting up, set the rotary knob to 40°C until the desired temperature of the room or floor is reached. The rotary knob
should then be turned back until the LED goes out. Fine adjustments can be made over the next few days according to individual
requirements.
Temperature adjustment:
Sobald sich die Bodentemperatur stabilisiert hat, kann die Thermostat-
Einstellposition an die tatsächliche Temperatur angepasst werden. Messen
Sie die Temperatur mit einem genauen Thermometer. Entfernen Sie den
Drehknopf (1) und drehen Sie die Stange (D). Positionieren Sie dann den
Drehknopf so, dass die angezeigte Temperaturlinie der gemessenen
Bodentemperatur entspricht.
MAX./MIN. Set temperature limit:
There is a blocking mechanism behind the rotary knob (1). By loosening the
small screw (C), the temperature setting can be limited between 20° and 25
°C, for example. The red ring indicates the maximum temperature and the
green ring indicates the minimum temperature.
Please note:
Installation may only be carried out by a qualified electrician. The relevant VDE regulations must be observed.
According to VDE 0100 guidelines, mains connection cables must be laid separately from safety extra-low voltage cables.
lines. When connecting an inductive load (e.g. a contactor), any additional EMC interference suppression measures that may be
required must be taken. EMC interference suppression measures must be taken by the installation.
The unit is only suitable for use in dry rooms.
Guarantee:
The guarantee is 24 months from the date of purchase, upon presentation of the proof of purchase.
A guarantee can only be granted after an inspection of the appliance.
The unit may only be installed by a qualified electrician.
PEROBE Flächenheizungen GmbH & Co. KG • Am Vorderflöß 38 • D- 33175 Bad Lippspringe • www.perobe.de
1)
ON / OFF
I - ON
O – OFF
2)
Rotary knob for temperature
adjustment
3)
LED – Lights up during
heating operation
230V~, 50/60Hz
16 A
IP 20
5°C to 40°C
± 0,5K
NTC - sensor
Temperatures and resistances:
Temperatur °C
Resistance Ω
5 °C
4442 Ω
10 °C
3605 Ω
20 °C
2420 Ω
25 °C
2000 Ω
30 °C
1661 Ω
40 °C
1164 Ω
Status 2021