FAULT FINDING

Identify the exact cause of the appliance stoppage

The paddles do not turn:

 Make sure that you have indeed actuated (position 1) the respective switches (8)
 Check the mains power supply and the condition of the power supply lead.

Liquid drips from the distribution nozzle:

 Clean the flexible distribution spout (5) (a solid body is probable stuck inside).
 The flexible spout (5) is a consumable. For hygiene reasons, do not hesitate to
replace it regularly

The appliance overheats:

 Ventilation is required to ensure the proper performance of the appliance
 Make sure that the front and back ventilation vents (10) are not obstructed (leave a
gap of at least 15cm).
 Check that there is no dust on the condenser grid (clean using a soft brush)
o Access to the grid: remove the appliance side panels (9)

The temperature of the juice is too high:

 See previous section
 Depending on the volume of product and the ambient temperature, it is sometimes
necessary to wait several hours before reaching the desired temperature.
 If after stabilisation the temperature is inadequate, then adjust the thermostats (12)
(one per juice container; it is recommended that the same setting is used on all the
thermostats)
o Access to the thermostats: remove the appliance side panels (9)
 For multi-container appliances (2 or 3 containers),
with no liquid is not
o Frost quickly forms on the evaporation cup (4) and the thermostat is quickly
triggered, thus stopping the compressor. The other containers are no longer
cooled.
o Always fill the containers with a minimum of 5 cm of liquid

The appliance runs continually without cooling the juice:

 Have the system checked by a refrigeration engineer
 The refrigerant charge is stated on the appliance identification plate.
 Draining and filling the condensing unit is absolutely prohibited in any place not
equipped to collect such gasses.
 Do not use anything other than R134A