Installation Manual; General Information; Location; Assembling The Heater - Ferroli SKY ECO F Installations, Bedienungs Und Wartungsanleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 138
SKY ECO F

2 INSTALLATION MANUAL

2.1 General information

The heater must only be instal-
led by an authorized technical
installer, in compliance with all
instructions contained in this
manual, the UNE 26 standard,
and local regulations affecting
installation and exhaust.

2.2 Location

The combustion circuit is sealed off from the installation
environment, so the unit can be installed in any room.
Nonetheless, the installation site must be sufficiently
ventilated to avoid hazardous situations in the event of
a gas leak.
European directive 90/396/EEC establishes this safety
standard for all gas-powered equipment, including those
with a sealed chamber.
The unit can operate in a partially protected environment
in accordance with standard EN 297 pr A6.
This Water heater is able to operate in a partially pro-
tected place, within the ambient temperatures minimum
-5°C and maximum 60°C.
In any case, the unit must be installed in a location free of
dust, flammable objects or materials, or corrosive gases.
The unit may be installed on a wall.
Attach it to the wall in accordance with the dimensions
indicated in section 4.1. The wall installation must be firm
and stable.
If the unit is installed inside a cabinet or
joined laterally to other elements, space
must be allowed for removing the casing and
performing normal maintenance activities.

2.3 Assembling the heater

Before assembling the heater,
make sure the water and gas
connections are properly secu-
red, identified, and positioned.
See the dimensions and con-
nections in section 4.1.
1 - O pen the packaging, and you'll find an assembly tem-
plate for the unit inside. Place it on the wall at the
appropriate height (be sure to observe the distances
described in the previous section), and make sure the
template is as horizontal as possible (using a level).
2 - M ark the position of the attachment holes.
3 - W ith a drill and Ø8 mm bit, make the holes and insert
the expansion plugs.
cod. 3541S170 - Rev. 04 - 09/2019
A
A
B
fig. 7 - Minimum distances
A
On each
>2cm
>50cm
B
-
C
In front
>2cm
83