Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Cross Tools CAS 600 EU Original-Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Translation of the Original Operating Instructions
Do not suck soot and flammable substances!
Use the ash vacuum cleaner never without for this device original filters.
Clean the filter as described in section 6.3 of the operating instructions after each use.
• If the unit is operating, be careful that the suction nozzle is not held on a sensitive part of the body, such
as eyes, mouth or ears.
• Never leave the appliance in operation unattended.
• Use this device only in dry conditions; the device may not be used when wet or in a humid environment.
• Suck water or other liquids.
• No embers or flammable substances such as explosive, toxic or harmful substances absorb.
• Before you suck ash, you must make sure that the ash has cooled sufficiently long and contains no more
embers. This can be determined by the ash is combed with a metal tool, before the ash vacuum cleaner
is used. From the cold ashes no perceptible heat radiation may emanate more.
• Constantly check when vacuuming hose and suction on warming!
• If the suction hose for the ash becomes warm during use, can turn off the power immediately and cool
down. Never empty the container in a combustible container!
• Before and after using the vacuum cleaner please empty and clean!
• Before any maintenance, cleaning, filter replacement or after use, turn off the device and unplug the
power cable. Let the appliance unattended and not to stand in the reach of children or those of their
actions are not aware.
• To clean the device, do not immerse in water or clean it with a water jet.
• Clean the engine cover, the surfaces and the container only with a damp cloth.
• Do not use aggressive solvents and / or detergents.
• Before you empty the tank, switch off the device and pull the plug from the socket.
• If the device is not in use, store it in a dry place or in buildings.
• Service and repairs may only be done by qualified personnel to avoid hazards. Defective parts of the
device may only be replaced with original parts.
Notes and instructions with the following symbols require particular attention:
Any non-observance of these instructions involves the danger of bodily harm to people and/or damage to
property.
Any non-observance of this instruction bears the risk of an electrical shock which may cause damage to
persons or property.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be informed
immediately, at the latest within 8 days after the date of purchase.

2. Technical data

Model
Mains voltage / frequency
Rated power
Degree of protection /
Suction power
Volume of airflow
Length of line cord
Length of suction hose
Length of metal nozzle
Diameter of metal nozzle
Tank volume
Net weight
Dimensions (B x T x H)
Item Part Nr.
8
CAS 600 EU
230 V ~ 50 Hz
600 Watt
IPX0 / ll
15 kPa / 150 mBar
22 l/s
4 m
1 m
20 cm
3.4 cm
12 l
~ 2,6 kg
26 x 26 x 36 cm
68522
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cas 600

Inhaltsverzeichnis