5-2-2. Resetting the Basic Settings

When the basic settings are reset and finalized (FINISH), all detailed settings will revert to their factory default
settings.
Power ON
Basic
settings
Approx.
Model
2 seconds
1-axis/2-axis model
Destination
country
Measuring unit
resolution
or
Detailed
settings
Minimum display
resolution
(Measuring unit
resolution)
For 2-axis and
3-axis models only
Display switching
(1-1, 2-2, 3-3)
For 1-axis and
2-axis models only
Axis label
switching
(1-X, 2-Y, 3-Z)
Scaling
(1.000000)
Compensation
value
(OFF)
Flicker control
(OFF)
Sleep
(OFF)
or
Start of operation
* When the segmented error compensation value is set,
the unit switches to reference point acquisition mode.
LH71
LH71
(General-purpose Applications and Milling Machine Function)
Standby key lamp
(Hold down for
(Lights up → flashes)
approx. 3 s.)
3-axis
model
2
Use
to select setting content
3
Select axis
Use
to select setting content
Performed for each axis.
Use
Note 1
4
Select axis
Use
and
Performed for each axis.
5
Select axis
Use
to select setting content
Performed for each axis.
6
Select axis
Use
to select setting content
Performed for each axis.
7
Enter the setting value
8
Use
to select the setting (compensation), and then set each option
Select axis
9
Use
to select setting content
!
Use
to select setting content
(When the minimum display resolution is 0.001 mm)
* If you have already entered the "detailed settings", make a note of the
setting values before resetting or changing the "basic settings".
* The setting in parentheses ( ) is the factory setting.
*
indicates the process when the setting does not
be changed.
1
Use
to select
to expand the selection option.
Note 1: Pressing
or
in the basic settings , and switches the
setting mode to detailed settings .
to select setting content
Enter the compensation value
Enter the
Enter the
position
compensation value
is displayed,
1 Select
GENERAL
2 STD/US/JPN
3 0.1/0.5/1/5/10/
00.00.01/
00.00.10/
00.01.00/
00.10.00
or
<Expanded>
0.05/2/20/25/50/
100/01.00.00
cancels the changes
4 Setting at 3 or
higher/Diameter
display at 3
(except for
angle)/Polarity
5 IN-1/IN-2/IN-3/
IN -
6 X/Y/Z
7 0.100000 -
9.999999
8 OFF/LIN Err/
SEG Err
* See Part 5-5,
"Compensation".
9 OFF/1/2
! OFF/1/5/10/30/
60
or
5. Settings
5-5
(E)