WARNING: lmproper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this appliance. lf the user cannot read or fully
understand the instruction manual, please contact your dealer. Supplier will not be responsible
for user's negligence.
APPLIANCE STAND AND LOCATION
The appliance is for outdoor use only. Do not use it for indoor or in an
enclosed area. Always ensure that adequate fresh air ventilation is provided.
- Always maintain proper clearance from combustible materials, i.e.
top 1000 mm and sides 500 mm minimum.
- Never operate appliance in an explosive atmosphe where gasoline or
other flammable liquids or vapors are stored.
CAUTION - Some parts of this product can become very hot and cause burns. Particular
attention should be paid to the presence of children and vulnerable people.
GAS REQUIREMENTS
- The gas governor, flexible gas rubber pipe and clamps, are not supplied with this appliance; buy
them according to National Rules in force and replace both taking into consideration expire
date, warnings of this lnstruction Manual and National Rules in force.
- Supply pressures to appliance:
- Nominal inlet pressure is 28-30/37/50 mbar
- Min inlet pressure: 20 mbar
- Max inlet pressure is: 50 mbar
- Gases to be supply: Butane, Propane or mixture of them
- Use gas governor approved according to Standard EN 12864, according to National Rules in
force; make sure it is in good condition and substitute it not over 10 years, as properly.
- Check the flexible gas rubber pipe and other gas connections, at least once per month and
each time the LPG Gas Cylinder is changed. lf it shows signs of cracking, splitting or other
deterioration, it shall be exchanged with a new flexible gas rubber pipe according to National
Rules in force of same length {but not over 1,5 m) and of the equivalent quality.
- The installation must be done according to National Rules in force.
- A dented, rusted or damaged LPG Gas Cylinder, maybe hazardous and should be checked by
your LPG Gas Cylinder supplier. Never use a LPG Gas Cylinder with a damaged valve connection.
- The LPG Gas Cylinder must be arranged to provide for vapor withdrawal from the operating
cylinder.
- Never connect a LPG Gas Cylinder without a gas governor, to the appliance.
- Disconnect the LPG Gas Cylinder when the appliance is not use.
LEAKAGE TEST
Gas connections on the appliance are leak tested at the factory prior to shipment. Possible mis-
handling of the appliance during the shipment might contribute to product integrity as a whole.
A complete gas leakage test must be performed again at the installation site. Please follow the
procedure below for leakage test.
- Make a soap solution of one part liquid detergent and one part water. The soap solution can be
applied with spray bottle, brush or rag. Soap bubbles will appear where a leak is present.
- Make sure the control tap is in the "OFF" position on the control panel.
- Turn on the gas supply and check for bubbles from the hoses and connections. Presents of
bubble means that a leak path is present.
- lf a leak is present, turn OFF the gas supply immediately, tighten any leaking fitting carefully, turn
gas again and recheck.
- Never leak test while smoking.