Do not smoke and avoid open fires and sparks at the storage location of the fuel and during
filling of the fuel tank. Fill up the fuel tank only at well-aerated locations and when the device is
turned off.
Do NOT overfill the tank (fuel level must be lower than the upper marking).
Do not spill fuel during filling. Spilled fuel and fuel vapours may catch fire. In case of spilled
fuel, make sure that the vapours evaporate before the generator is turned on.
Avoid long skin contact with fuel and breathing in fuel vapours.
fuel tank cap
7. Starting the generator
Make sure that no consumer is connected and the generator is leveled out. To avoid overheating,
assure that the ventilation under the generator is guaranteed.
1. The generator has a fully automatic cold start system with choke lever in position
open (Running). (If battery is sufficiently charged)
Alternatively (if the battery is not charged enough) you have to adjust
open
the choke lever into position closed (Start).
CLOSED
Choke
(Start)
upper level
OPEN
(Running)
54