  • DEUTSCH, seite 21
Flashing beacon function:
The electronic control unit is equipped with an output for the
management of the flashing beacon 230 Vac. Its function is
conditioned by motor motion and automatic closing which if
activated, enables the flashing beacon even during pause time.
Operation with TIMER:
The control unit can have a timer set up instead of an open-
close ( PUL ) control button.
Example: at 08:00 the timer closes the contact and the control
unit opens the gate. At 18:00 the timer opens the contact and
the control unit closes the gate. During the interval between
08:00 and 18:00, at the end of the opening phase, the control
unit disables the flashing beacon, automatic closing and radio
controls.
PROGRAMMING :
SEL key: selects the type of function to be stored, selection is
indicated by a flashing LED.
Repeatedly press the key to select the desired function. The
selection remains active for 10 seconds, (indicated by the
flashing LED); after 10 seconds, the control unit returns to its
original status.
The SET key: this programs the information according to the
type of function previously selected with the SEL button.
IMPORTANT: The function of the SET key can be replaced with
the radio control, if programmed previously (CODE led on).
MAIN MENU
The control unit is provided by the manufacturer with the
possibility of selecting a number of important functions.
---------------------- MAIN MENU -----------------
LED Reference
LED off
1) AUT / P-P
Automatic
2) CODE
No code
3) CODE PED.
No code
4) INB.CMD.AP
Disabled
5) T. MOT.
30 sec. motor time
6) T.MOT.PED.
Mot. Time Ped. 10 sec.
7) T. PAUSA
No auto close
8) RIT. ANTE
No gate delay.

1) AUTOMATIC / STEP BY STEP:

The default settings of the control unit have " Automatic "
operating logic enabled (AUT/P-P LED off), if you want to
enable the operating logic "Step by Step" (AUT/ P-P LED on), it
is necessary to enable it; use the SEL key to move to the
flashing AUT/P-P LED then press the SET key. AUT/P-P will
light up steadily. Repeat the procedure to restore the previous
configuration.
2) CODE: (Radio control code)
The control unit can store up to 150 radio controls with different
fixed or rolling codes.
Programming.
The transmission code is programmed in the following way:
using the SEL key to move to the flashing CODE LED, at the
same time send the pre-selected code from the radio control
you wish to use; when the CODE LED stays on steadily,
programming is finished. If all 150 available codes have been
memorised, by repeating the programming operation, all
programming LEDs will start to flash, indicating that it is not
possible to memorise any more codes.
Deletion.
All the stored codes are deleted as follows: press the SEL
button until the CODE LED** flashes, then press the SET button
and the CODE LED turns off and the codes are deleted.
LED On
Step by Step
Code entered
Code entered
Enabled
Programmed time
Programmed time
With auto close
Programmed time
3) CODE PED:(Code for the radio control Ped. / Anta S.)
The programming and deleting procedure is the same as the
one illustrated above except that the selected LED should be
for PEDESTRIAN CODE.
4) INB. CMD. AP: (Command inhibition during opening and
pause time, if entered)
The command inhibition function during opening and pause
time, if entered, is used when automation includes a loop
detector. During the opening or pause phase the control unit
does not receive the commands sent by the loop detector with
every passage.
The default settings of the control unit have disabled command
inhibition during opening and pause time. If it is necessary to
enable it, do the following: use the SEL key to move to the
flashing INB.CMD.AP LED then press the SET key. The
INB.CMD.AP LED will light up steadily. Repeat the procedure to
restore the previous configuration.
5) T. MOT and DECELERATION:
time of max 4 minutes)
The control unit is supplied by the manufacturer with a default
motor operation time of 30 seconds, without deceleration.
If it is necessary to modify the operating time of the motors,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT LED.
then press the SET key briefly. Motor 1 will start the opening
cycle; in correspondence with the point desired to start
deceleration press the SET key again: the T. MOT. LED. will
start flashing more slowly and Motor 1 will decelerate; when the
desired position is reached, press the SET key to complete the
opening cycle. The T. MOT LED will now start flashing normally
again and Motor 2 will begin its opening cycle:
operations to program the work time for Motor 2,
programming the opening times for the motors, Motor 2 will start
its closing cycle: repeat the same instructions as above for
programming the closing cycle of Motor 2 and then for Motor 1.
If you do not want the control unit to decelerate, when the
opening and closing phase is finished, press the SET key twice
during programming, instead of just once.
During programming it is possible to use the radio control key
located on the control unit, instead of the SET key, only if
previously memorised.
6) T. MOT. PED:
(Programming a pedestrian operating time of 4
minutes max.)
The control unit is factory supplied with a predefined
(Pedestrian) Motor 1 operating time of 10 sec. without
deceleration.
If it is necessary to modify the pedestrian operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT PED.
LED, then press the SET key briefly. Motor 1 will start the
opening cycle; in correspondence with the point desired to start
deceleration, press the SET key again: the T. MOT. PED. LED
will start flashing more slowly and Motor 1 will decelerate; when
the desired position is reached, press the SET key to complete
the opening cycle. At this point the T. MOT PED. LED will start
flashing at its standard pace again and the Motor 1 will begin
the closing phase; repeat the above operations for the closing
phase. If you do not want the control unit to decelerate, when
the opening and closing phase is finished, press the SET key
twice during programming, instead of just once.
During programming it is possible to use the radio control key
located on the control unit, instead of the SET key, only if
previously memorised.
7) T. PAUSA:
(Automatic closing time programming max. 4 minutes)
The control unit is factory supplied without automatic closing. If
you wish to enable automatic closing, proceed as follows: using
the SEL key to move to the flashing T. PAUSA LED, press the
SET key briefly, then wait for the amount of time you wish to set
for automatic closing; briefly press the SET key again, and in
(Programming a motor operation
repeat the
After

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis