Problem
There is too much frost
and ice.
The compressor does not
start immediately after
pressing the "FastFreeze"
or "FastCool", or after
changing the temperature.
Water flows on the rear
plate of the refrigerator.
Water flows into the refrig‐
erator.
Water flows on the floor.
Temperature cannot be
set.
DEMO appears on the dis‐
play.
Possible cause
The FastFreeze function is
switched on.
The FastCool function is
switched on.
The door is not closed cor‐
rectly or the gasket is de‐
formed/dirty.
The water drainage plug is
not correctly positioned.
Food products are not
wrapped properly.
Temperature is set incor‐
rectly.
This is normal, no error
has occurred.
During the automatic de‐
frosting process, frost
melts on the rear plate.
The water outlet is clog‐
ged.
Food products prevent that
water flows into the water
collector.
The melting water outlet is
not connected to the evap‐
orative tray above the com‐
pressor.
The "FastFreeze function"
or "FastCool function" is
switched on.
The appliance is in demon‐
stration mode.
ENGLISH
Solution
Refer to "FastFreeze func‐
tion".
Refer to "FastCool func‐
tion".
Refer to "Closing the door".
Position the water drain‐
age plug in the correct
way.
Wrap the food products
better.
Refer to "Operation" chap‐
ter.
The compressor starts af‐
ter a period of time.
This is correct.
Clean the water outlet.
Make sure that food prod‐
ucts do not touch the rear
plate.
Attach the melting water
outlet to the evaporative
tray.
Switch off "FastFreeze
function" or "FastCool
function" manually, or wait
until the function resets au‐
tomatically to set the tem‐
perature. Refer to "Fast‐
Freeze function" or "Fast‐
Cool function".
Keep the button pressed
for approximately 10 sec‐
onds until a long sound is
heard and display shuts off
for a short time.