Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time =100%)
Flow Rate
System Error
Calibration Funciont
Default parameters:

Language = UK

Set Point value= 7,4 pH; 750mV (Rx)

Dosing Method = Acid; Low (Rx)

Time OFA = OFF

Calibration = 7/4 (2 point); 465mV (Rx)

Flow Input= OFF

Code 0000136866
Display
Level____7,2_ph
OFA_Alarm__7,2_ph
OFA_STOP___7,2_ph
Flow_______7,2_ph
Parameter_Error
Error_7_ph
Error_4_ph
Error_465_mV
To restore Default parameters run Following steps:
rev. 1.0
Relay
Alarm Relay
Close
Alarm Relay
open
Alarm Relay
Close
Alarm Relay
open
Alarm Relay
Open
Alarm Relay
open

Power off Pool Basic unit

Keeping Press UP and DOWN Key switch on the
Power.
Init.default__no

The unit will flash
Init.default__Yes

Press up

Enter Key to restore Default parameters.
Actions to do
- Push Enter Key to open
Alarm Relay
- Restore Product tank
- Push Enter Key to reset
- Push Enter Key to reset
- Restore Flow Rate
- Press Enter Key to replace
Default parameter
- Destroy Unit
- Restore Probe or Buffer
solution and repeat calibration
function
6