2. Rotate the VOLTAGE control knob until "rPr" and "no" are displayed.
3. Rotate the CURRENT control knob until "rPr" and "YES" are displayed.
4. Press the CURRENT control knob once to reset the preset values. "YES" lights up when the values have been
successfully reset.
5. Press the VOLTAGE control knob to exit the MENU mode.

h) Remote control operation "Remote Ctrl"

Through the built-in "Remote control" connection (16), the voltage and current can be set through an external volt-
age source or an external adjustable resistance (short "poti"). The remote control is connected on the rear "Remote
Control" built-in plug (16). There is a remote socket included for connection.
In remote-controlled operation, the current control path must also be connected, since the output otherwise
switches to the current limitation mode "C.C." and limits the output voltage.
Preparation of the remote control connection
1
1. Turn the lateral screw of the supplied socket and remove the front, black contact socket turning it slightly.
2. Draw five connecting cables with a conductor cross-section of at least 0.34mm
rear. Carefully solder these cables to the soldering lugs no. 1, 2, 3, 4 and 5 of the black contact socket. Ensure
that no short circuits are created.
The numbers of the soldering lugs are indicated on the black insulator.
3. Mark the loose ends of the cables with the corresponding contact numbers (1-5) to avoid confusion.
4. Insert the black contact jack in the reverse order into the metal sleeve and screw them tight.
through the metal sleeve from the