RDS Technology SILACOUNT 200 Bedienungshandbuch Seite 3

Ballenwickel -monitor
Vorschau ausblenden Andere Handbücher für SILACOUNT 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
The Control Switches
There are three switches on the front panel used individually or in
combination to programme, set/reset or select a function.
Current No. of wraps
Programme Key
Not used
The Display
The left hand section shows the current number of wraps and the right hand
section shows the target number.
When the current number = Target number, the alarm will sound for 2
seconds and the display will flash. (If set, the early warning alarm sounds
beforehand).
Automatic reset of current number to zero normally occurs 3 seconds after
the Target number is reached. If additional wraps are added after the Target
number is reached, the current number will continue to advance.
Silacount 200 Bale Wrap Monitor
Target No. of wraps
Display Bale Total
Reset Part Total.
Set target wraps.
Zero current wraps
Not used
3