Herunterladen Diese Seite drucken

Elko EP RFIM-20B Bedienungsanleitung Seite 3

Funkgesteuertes universelles sendemodul
RFIM-20B, RFIM-40B
Wireless contact converter
EN
Funkgesteuertes universelles Sendemodul
DE
AT
Technical parameters /
Technische Parameter
Supply voltage:
Battery life:
Transmission indication / function:
Number of inputs:
Transmitter frequency:
Signal transmission method:
Range in free space:
Other data
Operating temperature:
Operating position:
Terminals
Length of terminals:
Resist.of connection between ter-
minals - for switched on button:
- for disconnected contact:
Mounting:
Protection:
Contamination degree:
Dimensions:
Weight:
Open contact voltage:
Length of cable to contact:
Related standards:
* RFIM-40B: on condition, that contact is permanently closed- battery life is approx. 1 month.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
Made in Czech Republic
Versorgungsspannung:
Lebensdauer Batterie:
Übertragungssignal / Function:
Anzahl der Eingänge:
Übertragungsprotokoll:
Signalübertragung:
Reichweite im Freien:
Andere Daten
Betriebstemperatur:
Einbauposition:
(CY wire, cross-section)
:
Terminal (CY Draht, Querschnitt):
Länge des Terminals:
Widerstand zwischen den
Anschlüssen - geschaltet:
- bei unterbrochenem Kontakt:
Einbau:
Schutzart:
Verschmutzungsgrad:
Abmessungen:
Gewicht:
Spannung bei geöff netem Kontakt:
Kabellängen:
Standards:
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
ELKO EP Germany GmbH | Minoritenstr. 7 | 50667 Köln | Deutschland | E-mail: elko@elkoep.de | Tel: +49 (0) 221 222 837 80
ELKO EP Austria GmbH | Laurenzgasse 10/7 | 1050 Wien | Österreich | E-mail: elko@elkoep.at | Tel: +43 (0) 676 942 9314
www.elkoep.com / www.elkoep.de / www.elkoep.at
RFIM-20B
1 x 3V battery / Batterie CR 2477
2 x 3V battery / Batterie CR 2032
5 years / Jahre *
orange / orange LED
2
866 MHz, 868 MHz, 916 MHz
unidirectionally addressed message / Directionale Nachrichtenübertragung
up to / Bis zu 200 m
-10 ... +50 °C
any / beliebig
2
4 x 0.75 mm
90 mm
< 300 Ω
> 10 kΩ
free at lead-in wires / Frei an die Anschlussdrähte
IP30
2
49 x 49 x 13 mm
45 g
pulse / pulse 12 V 
max. 100 m of parallel lines /
max.100 m paralleler Linien
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC) /
EN 60669, EN 300220, EN 301489 Richtlinie RTTE, RG Nr.426/2000 Sgl. (Richtlinie 1999/EG)
* RFIM-40B: bei dauerhaft geschlossenem Kontakt verringert sich die Lebensdauer der Batterie
auf ca. 1 Monat.
Achtung:
Bei der Installation Aktoren iNELS RF Control muss es der Mindestabstand 1 cm geachtet sein.
Zwischen aufeinanderfolgenden Befehlseingaben sollte mindesten 1s Abstand liegen.
Warnung
Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten.
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifi kation, nach dieser
Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott
zu behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle
Leitungen, miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und
der Wartung sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu
beachten. Berühren Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der
Sendeleistung des RF Signals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude,
in dem die Installation stattfi ndet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind nicht
für die Montage in Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht in
Metallschalttafeln und in Kunststoff -Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des RF-Signals
ist dann nicht gegeben. RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und abgeschirmt
werden, die Batterie des Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung durch eine
Steuerungseinheit.
RFIM-40B
red / rote LED
4
2
6 x 0.75 mm
50 g
3 V
max. 5 m
02-45/2015 Rev.3