TOPPING UP THE OIL-DYNAMIC CIRCUIT (fig. f8)
You need to top up the oil-dynamic circuit after a long period
of work, when you note a power loss. Put the riveting tool
(DWELL AND NOT FED) in a horizontal position and remove
the plug (F) and the nozzle (A) using the appropriate wrenches
provided with the tool. During this operation, check the oil
level in order to avoid any overflowing. Then, slowly pour the
oil HLP 32 cSt into the bellows container (O) which shall be
screwed to its seat on the plug (F). While keeping the riveting
tool in a horizontal position and starting air feeding, push the
tensile strength button and make the riveting tool carry out
some cycles until air bubbles inside the container (O) stop
coming out. This condition indicates that the topping up of
the oil has fully been achieved. At this point, while keeping the
riveting tool in a horizontal position, unscrew the oil container
(O) and close it again.
Do not push the tensile strength button during this operation.
Go on by closing the oil tank plug (F).
WARNING: it is very important to follow the about mentioned
instructions and use gloves and protection glasses or protective
visors. If you need to empty fully the hydraulic circuit, you must
put the oil in a suitable container and contact a Company that
is authorized to discharge any waste.
ATTENTION!
Before disconnecting the compressed air hose,
make sure that it is not under pressure!
ATTENTION: Make sure that the oil filler cap ( F )
is tightened at a torque corresponding to min. 5
Nm ÷ Max. 8 Nm.
We recommend to use oil HLP 32 cSt or similars.
min. 5 Nm
max. 8 Nm
f8