Positions 3 - 0 select the wind speed threshold after which the output contact closes.
The settings use the Beaufort scale:
0 = 10Bft (24.5 m/s = 88 km/h)
9 = 9Bft (20.8 m/s = 75 km/h)
8 = 8Bft (17.2 m/s = 62 km/h)
7 = 7Bft (14.1 m/s = 51 km/h)
6 = 6Bft (11.0 m/s = 40 km/h)
5 = 5Bft (8.0 m/s = 29 km/h)
4 = 4Bft (5.5 m/s = 20 km/h)
3 = 3Bft (3.3 m/s = 12 km/h)
After exiting test mode, wait for 4 seconds for the device to correctly read the selected
wind speed.
If you change the threshold, please wait 4/5 minutes for the device to read and save the
new value.
Helpful tips: To quickly change the thresholds, first select test mode, and set the new
value from here.
Terminal g can be used to connect up to a grounding cable.