2.3 Update procedure
The BC 141 can be updated via micro SD card or USB connection/computer. Please check the website
www.cashtester.com and/or contact your dealer for further instructions.

Troubleshooting and maintenance

3.1 Description of alerts and error messages
The unit stops the counting process in case of an alert or error and will display one of the following or
messages:
Alert
F-P
F-F (UV-fout)
F-C/F-1/F-2/F-3 (MG-fout)
F-7 / F-8 (IR-fout)
Ed / EL
ES
EJ / EC
Stacker Full
Error messages:
Error
Location
E00
UV sensor
E10
Hopper sensor
E11
Stacker sensor
E30
Left counting sensor
E31
Right counting sensor
E60-E6B
IR sensor
E70-E7B
E50
Rotation speed sensor
E80
Internal memory
3.2 Care and maintenance
Exchange of the fuse
1.
Disconnect the main power cable before opening the cover, otherwise you might risk an
electric shock.
2.
To exchange the fuse, please remove the cover first. Replace the cover properly after
exchanging the fuse.
Exchange of wear and tear parts
Exchange of other wear and tear parts only by Cashtester / Amwit Security B.V. and authorized dealers.
Reason
Difference in height of banknote
UV-feature not recognized
Magnetic feature not recognized
Infrared feature not recognized
Difference in size compared to note tested before
Folded banknote
More than 1 banknote feeded
Stacker full
How to solve the error
Check if the BC 141 SD is properly closed
Remove the banknote(s) and clean the hopper sensor
Remove the banknote(s) and clean the stacker sensor
Remove the banknote(s) and clean the internal part of the
machine by using pressurized air
Clean the feeding wheels
Reset to factory settings