Herunterladen Inhalt Inhalt Diese Seite drucken

Tempo Communications OPM510 Bedienungsanleitung Seite 19

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPM510 • OPM520 • SLS520 • SLS525 • SLS530 • SLS535 • SLS536
Two Test Jumper Method: Link Loss (cont'd)
1. If a complete test set (light source and optical power meter) is
   available at each end, it is advisable to test the output power of
   the sources and the condition of the test jumpers before
   commencing measurement of the link.
   Connect each source and optical power meter with a test jumper,
   as shown above. The sources should be set to continuous wave
   (CW) output mode. The power meters should be set to the correct
   wavelength and to dBm measurement units. Note the P1 and P2
   dBm readings. For example, a SLS520 1310 NM laser source
   should read approximately -1dBm on the optical power meter.
A
Test
jumper 1
Source
FORWARD LOSS (dB) = P1 – P3
Cable
plant
Test
jumper 2
P3
Power meter
B
19