10. Troubleshooting
If the appliance does not function properly, please check the below table for the solution.
If you are unable to solve the problem, please contact the supplier / service provider.
Problem
The appliance is too noisy. - Appliance is not supported properly.
- The appliance does not
cool sufficiently.
- Freezing time too long.
- The compressor starts
too often.
Exterior (7) surface is too
wet.
EN
11. Technical specification
Item no.
Operating voltage & frequency
Rated input power
Rated current
Refrigerant used and quantity
Energy efficiency class
Setting: Temperature range
Climate class
Protection class
Noise level
Foam blowing agent
Freezing capacity
Net volume
Net weight
Approx. dimension
Remark: Technical specification is subjected to change without prior notice.
20
Possible cause
- Before switching on, the appliance
has not stand still long enough (3
hours) to level off the refrigerant
- The lid does not close tight.
- The seal is not placed tight enough.
- Excessive ice formation on the inte-
rior walls of the appliance.
- The appliance is located near the
heat source (e.g. stove, heater, etc).
- Put too warm or too much food in-
side cabinet of the appliance.
- Humidity of the outside environment
is too high.
233801
105W
R600a / 52g
E
4,7 kg /24hr
93L
27 kg
(W) 574 x (D) 564 x (H) 845 mm
Possible solution
- Check if the appliance stands
stable (all four feet should be on
the floor firmly).
- Let stand still again before start
to oper the appliance.
- Contact the supplier
- Contact the supplier
- Time to perform defrost.
See = = > Cleaning and mainte-
nance
- Keep the appliance away from
the heat source.
- Cool down the warm food before
put inside the cabinet.
- Do not put too much food inside.
- Put inside a air-conditined room
to lower the humidity.
233818
220-240V~ 50Hz
0,8 A
R600a / 58g
-28°C to -14°C
T
Class I
< 60 dB (A)
Cyclopentane
7,2 kg / 24hr
(W) 754 x (D) 564 x (H) 845 mm
110W
F
140L
31 kg