USAGE & MAINTENANCE
The luminaire may only be used in an environment for which it has been designed according
to its rating plate.
Before performing maintenance, the voltage must be disconnected from the luminaire.
It takes several minutes for the luminaire components to cool down.
The luminaire may not be used without its cover glass or PC cover.
The condition of the installation rail and the bracket should be checked regularly.
A damaged luminaire must not be used; voltage must be disconnected from it and it must
be repaired.
An unstable electrical grid may damage the electronic components of the luminaires.
Temperature and the quality of the supply voltage affect the service life of the control gear.
The estimated failure rate is 0.2% per each 1,000 operating hours at the luminaire's maximum
allowed ambient temperature. However, a failure rate of 10% remains within normal limits.
Transients and voltage spikes significantly reduce the service life, as does an unclean
supply voltage.
The luminous emittance of LED luminaires has a tolerance of ±10%. The luminous flux of
LED light sources decreases over their service life, just like that of traditional light sources.
When an old LED luminaire is replaced with a new one, the difference in luminous emittance
may be evident to the naked eye due to the better lighting power of the new luminaire.
The colour temperature of the luminaire may also change.
The product is covered by the Waste Electrical and Electronic Equipment Directive 2012/19/EC
(WEEE), and must be properly recycled at the end of its service life.
The control gear of the luminaire can be replaced by a professional electrician, if necessary.
The control gear are in a separate control module. Switch off the power before replacing
faulty control gear. The replacement may only be performed by a professional electrician
in accordance with the local electrical safety regulations. Replacing the control gear (see
pictures on page 48):
• Loosen the 8 screws on the cover.
• Remove the cover and air lock.
• Loosen the 3 screws from the control gear bracket.
• Loosen the two screws from the control gear and remove the control gear.
20
I-VALO OY
a) Removing the wire from the control gear. Press a thin stick through a hole
located above the wire connector. This releases the wire.
b) When reinstalling the control gear and its bracket, make sure the control
gear is placed tightly against the luminaire body.
c) Ensure that the wires are not crushed against the control gear bracket and
the body.
|