Herunterladen Diese Seite drucken

Xtrails ADPRO PRO E Serie Kurzanleitung Seite 2

Werbung

Opening of housing bracket
Housing cover
TM
360PROtect
lens
Masking Detection lenses
Filter (window)
Bracket cover
Removal from mounting surface
tamper contact adjustment screw
Opening of housing
Bead
Notch
Locking screws
Compliant seal
Application of iCommission on swivel bracket
Telescopic sight mounting
block
(comes with alinment
telescope)
iCommission
Side covers w/
breakout cuts
for hose clamps
Bracket Tamper Adjustment
Pin assignment and output event selection
Label
Function
Pin
Description
1
Ground or AC
GND Supply
Power supply
10.5 - 30 VDC, 24 VAC ±15% auto-sensing
2
V+ or AC
A PS1 Class (15W) power supply according to EN62368 should be taken
V+ Supply
3
RS485 B
HLI (high level interface) for commissioning and real time alarm management
High level interface bus
RS485
RS485 A
4
5
Out 5
Freely programmable
Default: Creep zone alarm
output 5
(available for
6
H-versions only)
7
Freely programmable
Default: Anti-masking alarm
OUT 4
(available for
output 4
8
H-versions only)
OUT 1 (Alarm)
Freely programmable
9
Default: Alarms from main zone(s);
output 1
non H-version also creep zone and anti-masking alarm*
10
11
1 End (AE)
End of Line for output 1
End of line cabling. Refer to pin assignment
12
OUT 3 (Fault)
Freely programmable
Default: Fault: (low power, heating error, flash problems, wrong rotary switch
output 3
setting, power on sequence), anti-masking alarm (non H-version only)
13
14
OUT 2 (Tamper)
Freely programmable
Default: Cover open/Alignment change/Bracket open*
output 2
15
16
2 End (TE)
End of Line for output 2
End of line cabling. Refer to pin assignment
* The default output setting for anti-masking may differ from factory setup depending on the used firmware. Check the correct output settings via ADPRO
configuration tool to ensure a proper anti-masking output setup.
References
Documents / Tools available at http://www.xtralissecurity.com
ADPRO PRO E-PIR Installation Manual, Doc. No. 27386 (English) and 26570 (German)
Installation manual
ADPRO PRO E PIR System Setup Manual, Doc. No. 26571 (English) and 27332 (German)
Setup Manual
ADPRO PRO E Design and Planning Manual, Doc. No 27387 (English) and 26570 (German)
Design and Planning Manual
ADPRO PRO E PIR Introduction to PIR Technology, Doc. No 27385 (English) and 26568
Technology Manual
(German)
Configuration software
ADPRO PRO configuration software 9.46 or above, doc no 29650
Firmware & Firmware update tool
Setup Flashloader 2.0 (32 and 64 bit) or above
Firmware version 1.41 or above for PRO E-detectors
Tools and Accessories (not included)
• Screw driver ≥140 mm
• 4mm (532/») Hex/Allen key screwdriver
• Wire cutter
• Pole mounting straps or screws for wall mounting
• Alignment telescope with PRO E adapters (CH18000101)
• iCommission (CH12003001)
• IFM-485-ST USB Interface Module (CH19000301)
• PRO E-IPM IP Module (CH12005001)
Terminal block and pin assignments
End of Line
End of Line
Cabling
Cabling
R
R
Drilling holes dimensions (use this template for drilling)
Recommended fixing
8 mm
d
0
50 mm
h
1
L
40 mm
d
d
D
0
s
4.5 - 5 mm
d
S
47.5 mm
d
bracket guide
L
90 mm
S
F
2 Nm
h
A
B
L
S
F
d
L
bracket guide
D
1

Werbung