Care should be taken to avoid contact of oil with skin or eyes. OIL MAY BE HOT! Used oil should be properly disposed of
in a leak-proof corrosive-resistant container according to local regulations.
• After every evacuation, while the pump is warm and oil is thin, take a small sample of oil from the drain port.
• If the oil is contaminated, drain the oil by placing the pump on a level surface and opening the oil drain valve. Catch
the waste oil in a container and properly dispose of it.
• If the pump has been sitting for more than one month, the oil is considered contaminated regardless of appearance
and should be changed as outlined above.
• To add oil, close drain, remove the oil fill cap and fill to the Oil Level Line with fresh oil.
5. INTAKE CONNECTIONS
Replace all caps and finger-tighten. Do not use caps with damaged or missing O-rings and always store vacuum pump
with capped ports to prevent dirt and moisture contamination.
6. PUMP MOTOR
The PUMP and OIL must be above 30˚F (-1˚C). The line voltage must be equal to the rating on the motor nameplate
±10%. Normal operating temperature is approximately 160˚F (71˚C), which is HOT to the touch! Line voltage and ambient
temperature will affect the normal operating temperature. Your vacuum pump is designed for continuous duty and will
run for extended periods without overheating. The motor has an automatic resetting overload protection feature. If the
motor will not restart the pump after shut-off, it may have opened the thermal protection. Disconnect the pump from the
system, wait about 15 minutes for the motor to cool down and then try again.
RETURNING A PUMP
Please fax a request for a return authorization number to 973-252-2455. This applies to both warranty and non-warranty
service!
Pumps returned for service without a return authorization number will not be accepted. In your fax, include your NAME,
ADDRESS and PHONE NUMBER along with a detailed explanation of the problem. We will contact you (i.e. your phone
number) to discuss your problem and determine if you have to return your pump. If you have to return your pump, we will
issue you an RMA #. Then, please follow the instructions below.
• Drain oil, cap all ports and place tape over the exhaust cap. If you fail to do this, your pump will not be accepted and it
will be returned!!!
• Use the original shipping box and inserts if available. Shipping damages are impossible to claim on used machinery.

LIMITED WARRANTY INFORMATION

The Vacuum Pumps are warranted against defects in material and workmanship for a period of one year. This warranty
does not cover failure due to abuse, improper usage, or progressive wear and tear. Warranty becomes valid to the original
owner and is effective on the purchase date. WARRANTY SERVICE IS PROVIDED THROUGH THE FACTORY ONLY. Please
contact the service department toll free (1-888-825-6989) for parts, service concerns, or to obtain a return authorization
number for warranty repair.
WARNING: This product can expose you to chemicals including lead and Di (2-ethylhexyl) phthalate, which are known
to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov