Intercom Server GE 800
Rack housing in 19" technology with 14 free slots for cards in Euro format. Fix
slots for the included G8-GEP processor card, G8-NET networking card and
G8-GEN power supply card.
Extent of supply
GE 800 housing
G8-GEN (Power Supply Card)
G8-GEP (Processor Card )
G8-NET (Connection Card)
G8A-GEN (Installation Board)
G8A-NET (Installation Board)
Depending on variant: Country specific transformer
Connection G8A-GEN
G8A-GEN
Music /
alarm
input
MU1
1
MU2
Floating
IN1
2
contacts
3
IN2
4
5
S1
S2
S1W
S1W
S1
S1
Programming socket
S2W
S2W
(parallel to G8-GEN)
S2
S2
+30V
DC
Power supply GE 800
or
24V AC
AC
24V AC
e.g.:
Grounding point
for wrist strap
Door opener
Grounding
grounding
Power supply
Installation
Installation boards
Plug-in cards
Connection G8A-NET
1....GND
(Shield)
6
2....TXD
7
3....RXD
4....NC
8
UPLINK
Ethernet (configuration)
5....GND
9
6....NC
7....NC
8....NC
9....NC
DOWNLINK
OUT (GEV)
Connection to network cards (G8-CNET-W, G8-CNET-E1)
or GE 700 (G7-GEV)
IN (GEV)
Tool for removing
of installation
boards
Card G8-GEN
Indication power supply
ON
Mains switch Intercom Server
OFF
RS232 (for configuration)
Fuse 3.15A
(slow blow)
Card G8-GEP
Status LED
1
2
3
4
DIP-switch
Latest software and documentation
To download the latest software and documentation,
enter the PIN-Code to the right at
www.software-manuals.com
Attention
Defective power cables of the transformer may not be repaired or changed. In case of defec-
tive power cables, the whole transformers must be changed.
Mounting and installation of the Intercom Servers and of the equipment may be carried out
by authorised service personnel only.
Warning: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Before exchanging of cards, ESD precautions must be observed. The Earth terminal
of the installation board G8A-GEN is used as grounding point for Wrist Strap Groun-
ding. Cards may be exchanged only while the voltage is switched off.
If heavy electromagnetic interference is to be expected (industrial environments), then
grounding of the Intercom Server is mandatory.
Manufacturer's reference
This equipment fulfils the requirements of the EU standard EMV-RL