6.11.1 Circuit Diagram for 24V BG 95 Motors
without safe switch off
example:
connection of a switch/sensor
from logic /PLC
U+
GND-
power supply
soft start circuit
0.5 ohms
> 50 W
U+
from
power supply
GND-
* MCB: Miniature circuit breaker, use DC-suitable UL listed inverse-time circuit breakers.
Select the rated current of the circuit breaker according to the used wire diameters.
6.11.2 Circuit Diagram for 48/60V BG 95 Motors
without safe switch off
example:
connection of a switch/sensor
U+
from logic /PLC
GND-
power supply
soft start circuit
1.2 ohms
> 50 W
U+
from
power supply
GND-
* MCB: Miniature circuit breaker, use DC-suitable UL listed inverse-time circuit breakers.
Select the rated current of the circuit breaker according to the used wire diameters.
Earth the system for functional reasons (EMC).
X
Page/Seite 46 / 51
example:
signal lamps/actors
MCB*
A-type 2A
...to next motors
2x MCB*
0.5 ohms
B-type 25 A
> 250 W
...to next motors
example:
signal lamps/actors
MCB*
A-type 2A
...to next motors
2x MCB*
1.2 ohms
B-type 25 A
> 250 W
...to next motors
6.11.1 Schaltplan für 24V BG 95 Motoren

ohne sicherer Abschaltung

M16 Signal
Connector
A
IN 0
B
IN 1
C
IN 2
D
IN 3
E
OUT 1
F
OUT 2
G
AI +
H
AI -
J
U Logic
K
GND Logic
L
IN 4
M
OUT 3
-
M23 Power
Connector
BALLAST
A
~
U-POWER
B
GND-POWER
C
no connection
D
U-POWER
E
GND-POWER
F
BG95 dPro
connect housing to machine earth
for EMC shielding
6.11.2 Schaltplan für 48/60V BG 95 Motoren
ohne sicherer Abschaltung
M16 Signal
Connector
A
IN 0
B
IN 1
C
IN 2
D
IN 3
E
OUT 1
F
OUT 2
G
AI +
H
AI -
J
U Logic
K
GND Logic
L
IN 4
M
OUT 3
-
M23 Power
Connector
BALLAST
A
~
U-POWER
B
GND-POWER
C
no connection
D
U-POWER
E
GND-POWER
F
BG95 dPro
connect housing to machine earth
for EMC shielding
System aus funktionalen Gründen (EMV) erden.
X
BG 95
dPro
Alternative: Industrial Ethernet
M12 CAN
from control unit
female Con.
CAN H
4
CAN L
5
M12 CAN
to next device (optional)
male Con.
CAN H
4
CAN L
5
M12 Encoder
interface
GND ENC
1
U ENC
2
1-A
3
1-B
4
2-A
5
2-B
6
3-A
7
3-B
8
M
Alternative: Industrial Ethernet
M12 CAN
from control unit
female Con.
CAN H
4
CAN L
5
M12 CAN
to next device (optional)
male Con.
CAN H
4
CAN L
5
M12 Encoder
interface
GND ENC
1
U ENC
2
1-A
3
1-B
4
2-A
5
2-B
6
3-A
7
3-B
8
M
Version 04-02-2021