Function
IRCW detects motion within an area and sends signals to a receiver to
activate for example ventilation or heating. It is designed to work with a
Regin wireless receiver with Modbus communication.
Technical Data
Supply voltage
CR123A 3V lithium battery x 1 (included at delivery)
Battery life
6 years
1
Frequency
868 MHz
Range, frequency
Over 300 meters in unobstructed space
Ambient
-10...+45 °C
temperature
Ambient humidity
Max. 85 % RH, non-condensing
Protection class
IP20
Dimensions, exter-
Ø 106 mm x 30,3 mm
nal (WxHxD)
Mounting position
2.7 ...4 m above the floor
Range, detection
Ø 6...8 m
1. Battery life is calculated with an average of 20 activations per day
Installation
The detector is equipped with a tamper switch inside the device. When
the detector is mounted correctly, the tamper switch will be compressed.
When the detector is removed from the back cover, the tamper switch
will activate and the detector will send a signal to the receiver.
Choosing position for detector mounting
For best coverage, the detector should be mounted on the ceiling at a
height of 2.7 to 4 meters above the ground. The detection diameter is
approximately 6 meters when the detector is mounted on a height of 2.7
meters, and approximately 8 meters when mounted on a height of 4
meters. See Figure 1.
Figure 1 Detection range at a height of 4 m and 2.7 m
Mounting
1. Break through the knockouts on the inside of the back cover. See
Figure 2
2. Screw the back cover to the ceiling through the knockout holes.
3. There are numbers on the back cover hooks that correspond to
numbers on the holes on the back side of the main body. Align the
holes with the back cover hooks.
4. Install the main body to the back cover. Rotate the main body
clockwise to lock the hooks in the holes.
IRCW
A
1
+
-
2
Figure 2 A = Main body, front, B = Main body, back, C = Back cover
Number
Description
1
Connection/Test button/ LED light
2
IR detector
3
Tamper switch
4
Mounting holes
5
Knockouts (on the inside)
6
Mounting hooks
N N o o t t e e ! ! Do not mount the detector:
– Where the view is obstructed by e.g. curtains, ornaments etc.
– Directly facing a door contact (DCW), since the signals can interfere
– In direct sunlight
– Where the temperature can rapidly change, e.g. in an area with an air
condition unit
– Directly facing heat sources, e.g. boilers, open fires
– Above a radiator
– Where there are moving objects in the detection area, e.g. curtains
B
3
4
1

Werbung

loading

Inhaltszusammenfassung für Regin IRCW

  • Seite 1 Figure 2 A = Main body, front, B = Main body, back, C = Back cover Function Figure 1 Detection range at a height of 4 m and 2.7 m IRCW detects motion within an area and sends signals to a receiver to Number Description Mounting activate for example ventilation or heating.
  • Seite 2: Installation

    Funktion IRCW upptäcker rörelse inom ett område och skickar en signal till en Handling mottagare för att aktivera till exempel ventilation eller värme. Den är Figur 1 Övervakningsområde vid 4 m och 2,7 m höjd.
  • Seite 3: Technische Daten

    Manipuleringsskydd Monteringshål Funktion Hantering Håltagningar (på insidan) IRCW Erkennt Bewegung innerhalb eines Bereiches und sendet Signale Monteringskrokar Lysdiod an einen Empfänger, um beispielsweise die Heizung oder Lüftung zu aktivieren. Das Gerät wurde für die Nutzung mit einem Regin Under normal drift kommer lysdioden inte att tändas när detektorn N N o o t t e e r r a a ! ! Detektorn ska inte monteras: Funkempfänger mit Kommunikation via Modbus entwickelt.
  • Seite 4: Montage

    Für RCW-M32: Die Testtaste drücken, um die Anzeige zu aktivieren. 2. Den Sockel durch die Öffnungen an der Decke festschrauben. 3. Die Häkchen am Sockel sind entsprechend der zugehörigen Löcher an der Rückseite des Geräts nummeriert. Die Löcher an den Häkchen des Sockels ausrichten. IRCW...
  • Seite 5: Bedienung

    Bedienung Fonction Im normalen Betriebsmodus leuchtet die LED nicht auf, wenn der IRCW détecte les mouvements dans un périmètre déterminé et envoie Bewegungsmelder aktiviert wird. des signaux à un récepteur pour activer la ventilation ou le chauffage, par exemple. Il est conçu pour fonctionner avec un récepteur sans fil Blinken: Wenn im Testmodus Bewegung erkannt wird Fig.
  • Seite 6: Mise En Service

    Appairage/test de connexion La connexion au récepteur doit être testée avant de monter le détecteur. Regin France , 32 Rue Delizy, 93694 Pantin Fig. 2 A = Structure principale, avant, B = Structure principale, arrière, C = Couvercle Tél. : + 33 (1) 41 83 02 02, Fax : +33 (1) 57 14 95 91 1.