Heizkreis / Heating Circuit QM../QH..
4. Technical Data
Rated voltage:
Ambient-/work piece
temperature range:
Max. length of heating
circuit:
Additional information can be found in the EC-Type Examination Certificate
5. Safety Advices
Heating circuits are only allowed to be used for permitted applications.
Ex-protection of heating circuits type: QH... is only guaranteed in original condition.
Electrical heating circuits are only permitted to be used/operated if undamaged.
Ex protection is not or even no more granted under the following conditions:
Damaged or carved isolation layers of supply cable or heating cable.
Power supply cable or end termination is carved or cracked.
The sealing compound of the shrink tubing (hot-melt adhesive) does not adhere to the outer jacket of
the heating tape or to the insulation of the connection cable.
Heat shrink is visually damaged due to overheating during assembling.
U
277 V AC
max.
ILL, ILLW, ILM with crimp terminals: -20°C/-25°C to +85°C
ILL, ILLW, ILM with terminal block: -20°C/-40°C to +65°C/85°C
ILH and ILS with crimp terminals: -55°C to +180°C
according to Quintex data sheets heating cable