Herunterladen Inhalt Inhalt Diese Seite drucken

Directions For Use - Berner 99989 Bedienungsanleitung

Kühler-vakuum-befüllgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB

Directions for use

Vacuum-type cooling system filler, no. 099989
The KVB 01 and KVB 01.1 permit repaired cooling systems to be checked for
leaks and refilled free of any air pockets.
To connect the KVB 01 to the cooling system expansion tank, a radiator adapter with con-
necting nipple is also required (corresponding to vehicle model – see accompanying list of
adapters).
V1
KVB..
A
(Illustr. 1)
!
Exercise caution when dealing with a hot cooling system 0 giving rise to a risk of scald injury!
Preliminary tasks/requirements
The expansion tank of the cooling system has to be empty.
.
Check the capacity of the cooling system (refer to vehicle user's manual).
.
Compressed air supply at 6-10 bar (87-145 psi).
.
1-2 litres more than the volume of the coolant system being filled. Particles of rust
.
and dirt must not get into the coolant system being filled under any
circumstances.
It is advisable to work with a container marked with a scale showing coolant level.
.
The best results will be achieved if the coolant container is at the level as the expansion
.
tank in the vehicle.
Set the heating control switch (in the vehicle) to the 'high heat' position.
.
G
V2
H
C
B
D
E
F
A
= Filling tube
B
= connection venturi tube
C
= Venturi tube
D
= Tube
E
= Adapter
F
= Expansion tank
G
= Vacuummeter -1 to 0 bar
H
= Connection compressed air
V1, V2 = Stopcocks
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis