Secondary Device Functions (continued)
Signal Delay Input
With Signal Delay Input, the internal binary signal source
can be selected. Input contains a list of the internal binary
signals .
Signal Delay Mode
With Signal Delay Mode, the current mode of the signal
delay function can be selected.
Value
Meaning
Description
0x00 (0) Deactivated
Deactivated
0x01 (1) Delay
On, Off and On-/Off delay
function
0x02 (2) One-Shot
One-Shot function
Tab. 5-3:
Activate/deactivate signal delay status
Signal Delay On-Delay
With Signal Delay On-Delay, the time for On-Delay can be
set. The value represents the time in milliseconds. The
value range is between 0x0000 (0) and 0xFFFF (65535). A
value of 0x0000 (0) represents no delay. The parameter
has no effect in One-Shot-Modus.
Signal Delay Off-Delay / One-Shot
With Signal Delay Off-Delay / One-Shot, the time for
Off-Delay and One-Shot can be set. The value represents
the time in milliseconds. The value range is between
0x0000 (0) and 0xFFFF (65535). A value of 0x0000 (0)
represents no delay.
Signal Delay Status
With Signal Delay Status, the current status of each
channel can be read.
Value
Meaning
Description
0x00 (0)
Off
Output signal of Signal Delay
= 0/FALSE
0x01 (1)
On
Output signal of Signal Delay
= 1/TRUE
0x02 (2)
On-Delay
Output signal of Signal Delay
= 0/FALSE and On-Delay
currently running.
0x03 (3)
Off-Delay
Output signal of Signal Delay
= 1/TRUE and OFF-Delay
currently running.
0x07 (7)
One-Shot
Output signal of Signal Delay
= 1/TRUE and One-Shot
Signal currently running.
0xFF (255)
Deactivated
Feature is deactivated.
Tab. 5-4:
Activate/deactivate signal delay status
www.balluff.com
5.1.5

System Commands

Command
Device Action
Value
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings – Resets writable
parameters to the default value.
Tab. 5-5:
Signal delay – System Commands
For an overview of all System Commands, see section 3.5
on page 19.
5.1.6
Variant Dependence
The functionality is available in all variants.
english