Digital position indicator
4
Primary Device Functions (continued)
Display Orientation
If the BDG is mounted upside down, the display can be
rotated through 180° for better readability.
Value
Meaning
0x00 (0) Not rotated
0x02 (2) Rotated
180°
Tab. 4-25: Possible values for Display Orientation
Display Brightness
The display brightness can be adjusted.
Value
Meaning
0x00 (0) Nominal
value
0x01 (1) Stage 1
0x02 (2) Stage 2
0x03 (3) Stage 3
0x04 (4) Stage 4
0x05 (5) Stage 5
Tab. 4-26: Possible values for Display Brightness
Display Power Mode
The display can be switched off permanently or with a time
delay.
Value
Meaning
0x00 (0) On
0x01 (1) Off
0x02 (2) Off (delayed)
Tab. 4-27: Possible values for Display Power Mode
38
english
Description
Display is shown in normal
orientation.
Display is rotated through
180°.
Description
Default value if the brightness
setting is not supported.
If supported, the nominal value
corresponds to the medium
brightness (stage 3).
Lowest brightness
Low brightness
Medium brightness
High brightness
Highest brightness
Description
The display is switched on and
works as configured (default).
The display is not supplied
with power. All segments are
switched off.
The display is switched off
after a predefined timer delay.
This delay time can be set
under Shutdown Timer Value.
Shutdown Timer Value
The Shutdown Timer Value parameter sets the shutdown
time in seconds (one increment corresponds to one
second, 0...86400 s (1 day), default: 10 s).
Ring Display Segment Resolution
The Ring Display Segment Resolution parameter can be
used to set how many micrometers correspond to one
segment on the LED ring.
For example, if the parameter is set to 200 μm and the
difference between the target and actual values is 1250
μm, 7 elements will light up on the ring display (one
increment corresponds to one micrometer, 1...10,000,000
µm (10 m), default: 1000 µm).
Display Mode (only BDG DA160-...)
This is a selection between predefined display contents.
The parameters can only be edited with BDG_DA1...
Value
Meaning
0x00 (0) Absolute
position
0x01 (1) Absolute
position
(swapped)
0x02 (2) Difference value
0x03 (3) Difference value
(swapped)
Tab. 4-28: Possible values for Display Mode
Scale Unit (only BDG DA160-...)
The displayed value can be divided by a power of ten to
change the displayed unit:
Displayed value = Value / 10
Scale Unit
Value range: 0...6 (Default: 0)
Number of Digits (only BDG DA160-...)
The Number of Digits parameter is used to specify the
number of visible digits on the display. There is no
rounding, the source value remains unchanged.
Example of the value 23.421:
If the number of digits is 0, the display shows the value
23.
If the number of digits is 2, the display will show the
value 23.42.
Value range: 0...5 (Default: 0)
Number of Rounding Digits (only BDG DA160-...)
The Number of Rounding Digits parameter can be used to
determine the display digit to which rounding is performed.
Value range: 0...5 (Default: 0)
Description
Line 1: Actual value (µm)
Line 2: Target value (µm)
Line 1: Target value (µm)
Line 2: Actual value (µm)
Line 1: Difference value (µm)
Line 2: Target value (µm)
Line 1: Target value (µm)
Line 2: Difference value (µm)