ton (B) (see fig. 7).
Press the select button until the LED (B) flashes
green three times.
The channel will be switched on or off for 15 minutes.
Afterwards, normal operation will be continued for the
heating zone.
8.2

Activating/deactivating the pump control

If you want to use connection terminal (H) for controlling
a heating pump, the heating zone can be switched to
pump control directly via the device. To do this, proceed
as follows:
Press the select button (B) until the LED of chan-
nel 1 starts flashing green (see fig. 7).
If the LED of channel 1 starts flashing slowly, the
pump control is activated. If the LED of channel 1
starts flashing quickly, the pump control is deac-
tivated.
If you do not want to change any parameters, you
can exit the menu by pressing the select button
(B) briefly.
To switch the parameter from activated to de-
activated or from deactivated to activated, press
and hold down the select button (B) for at least
4 seconds.
Manual operation