4.2 Foreseeable misuse

The system is not approved for use in healthcare areas and facilities (e.g. hospital, rest or
retirement home, nursing home etc.)
 In damp or extremely humid environments or outdoors
 Without a bed frame, directly on the floor
 As a lifting device for heavy loads etc.
 For all other forms of application that are not in accordance with correct use
In cases of non-compliance, the manufacturer will accept no responsibility whatsoever.
If an intervention is performed on the system by a person or persons not authorised to do
so by Hettich Franke, all warranty and liability claims concerning the complete drive unit
will also be terminated. This also applies to cases of incorrect assembly and dismantling,
incorrect use, incorrect treatment and incorrect operation, or if any other damages should
exist for which Hettich Franke has no responsibility.

4.3 Disposal

 When disposing of a drive unit that is no longer in working order, please observe the
applied environmental protection regulations of the respective country
 The disposal of the batteries is regulated in the EU by Battery Directive 2006/66/EC, in
Germany by the BattG battery law and internationally by any applicable national laws
and regulations.
 The disposal of the product is regulated in Germany by Elektro-G, internationally by the
EU Directive 2012/19/EC (WEEE), or by any applicable national laws and regulations.
ATTENTION
 Never recharge the batteries! Explosion hazard!
 Keep the batteries out of children's reach, do not throw into fire, do not short-circuit or
take batteries apart
 If necessary, clean the battery and appliance contacts before inserting
 Remove exhausted batteries from the appliance immediately! Increased risk of leakage!
 Do not expose the batteries to any extreme conditions, e.g. by placing on top of heaters
or by exposing to direct sunlight! Increased risk of leakage!
 Avoid contact with skin, eyes and mucous membranes. In case of contact with battery
acid, immediately rinse the affected areas with lots of clear water and seek medical
attention right away

5 Technical data

Mains voltage:
Power consumption*:
Motor voltage:
Protection type:
Adjustment time for max. lift**:
Max. torque:
Max. continuous operation:
Rotation angle:
Dimensions (length x width x height):
Control options:
Frequency range of radio control:
Batteries (radio remote control):
Operating current:
Ambient / storage conditions
Room temperature:
Relative humidity:
16
230 V AC
70 W
24 V DC
IP 20
approx. 9.5 s
250 Nm
2 min
approx. 70°
232 x 178 x 110 mm
Hand set
433 MHz
2 times LR6 1.5V
12 mA
from +10°C to +40°C
from 30 % to 75 %