Remote control
It is possible to use an external remote control to turn on and off the inverter (see detail # 3). The inverter must be switched to either
"ECO" mode or "On" mode and then be turned off by the remote control. When the inverter is switched "on" by the remote control it will
use the mode set on the inverter itself ("On" or "Eco").
LED indicator
The inverter is equipped with protection against wrong usage or connection. There is a LED (see detail # 1) indicating status.
In addition, the inverter includes a beeper, which will sound in some alarm situations.
The different LED indications are explained below:
Characteristic
Normal Inverting
Initial state, no output
External AC in
ECO mode searching
Observe all Errors are shown with either orange or red blinking. When
the inverter is shutting down.
Blinking pattern is shown in repeated sequences:
Low Battery Voltage
High Battery Voltage
Inverter overload
Too high temperature
Ground failure
(OVER current leakage)
Beeper mode
Inverter start up
Warning
Shutdown

NORMAL OPERATION

LED indicator
ERROR
Warning:
Shutdown:
Warning:
Shutdown:
Warning:
Shutdown:
Warning:
Shutdown:
Warning:
Shutdown:
BEEPER FUNCTION
Number of Beeps
1
2
8
Condition
Solid Green LED constantly.
Solid Orange LED constantly.
Solid Red LED constantly.
Green LED long interval blink (1,4 sec on, 1,4 sec off), Repeat
until goes to another state.
orange blinking there is a Warning,
On time [seconds]
0,2
0,6
0,6
while when there is
red blinking
Off time [seconds]
0,2
0,6
0,6
5