Herunterladen Inhalt Inhalt Diese Seite drucken

Peraqua 7300704 Installations- Und Benutzerhandbuch Seite 30

Inverter wärmepumpe für swimmingpool
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

For power supply: 230V 50Hz
Power Supply
230V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
The swimming pool heater must be earthed well.
3. Electric Wiring Diagram
Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Rated Residual
Action Current mA
Fuse
Power Cord
Signal cable
※ Above data is subject to modification without notice.
Note:
The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire
diameter must be increased. The signal cable can be extended to 50m at
most.
4. Installation instruction and requirement
The heat pump must be installed by a professional team. The users are
not qualified to install by themselves, otherwise the heat pump might be
damaged and risky for users' safety.
Distribution Box
(Customer prepare)
Fuse
Breaker
7300704
8.0
30
A
8.0
(mm
)
2
3×1.5
(mm
2
)
3×0.5
Swimming Pool Heat Pump Wiring Board
Power Cord
7300706
7300707
9.5
15.0
30
30
9.5
15.0
3×1.5
3×2.5
3×0.5
3×0.5
7
7300708
7300709
20.5
23.5
30
30
20.5
23.5
3×4
3×6
3×0.5
3×0.5

Quicklinks ausblenden: