Maximum safety
Delta-peak sensitivity: The automatic charge termination program works on the
principle of the Delta-peak voltage detection. (NiCd/NiMH)
Auto-charge current limit: When charging NiCd or NiMH at 'AUTO' current
mode, you can set the upper limit of change current to avoid from high current
charging. This is very useful when charging the low impedance and small
capacity NiMH battery in 'AUTO' mode.
Capacity limit: The changing capacity always calculated by multiple of the
charging current and time. If the charging capacity exceeds the limit the process
will be terminated automatically when you set the maximum value.
Temperature limit: The temperature of the battery on charging will rise by its
internal chemical reaction. If you set the limit of temperature the process will be
expired forcibly when the limit has reached.
Processing time limit: you can also restrain the maximum process time to
prevent from any possible defect.
Automatic cooling fan: The electric cooling fan comes into action automatically
only when the internal temperature of the unit is raised.
Data store/load
For users convenience it can store maximum 5 data of each battery type. You
can establish the data contains program setting of the battery to charge or
discharge continually. These data can be called out at any time you need and
the process can be executed without program setting.
Cyclic charging/discharging
Perform 1 to 5 cycles of charge>discharge or discharge>charge continually for
battery refreshing and balancing.
-2-