Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

INSTALLATION

This airconditioner must be connected to an electrical circuit which includes on building side a 16 A circuit
breaker. It is to place away from easily combustible materials and a free space of 30cm around the appliance.
A 30 mA residual current device is recommended additionally. In case of using an extension cable only use
proper diameters, in case of multiple sockets do not overload it. The airconditioner must be placed on a flat
floor with sufficient load capacity.
INSTALLATION - Installing heat exhaust
1. Choose a place near a window and socket to
place the device.
2. Screw the two plastic exhaust hose ends (figure
1, No. 14) onto the exhaust hose (see figure 2).
3. Install the drainage hose onto the hot air outlet
(10) on the back of the device (see figure 2).
ATTENTION:
To prevent breaking, the exhaust host can only
be twisted or deformed to a certain limit.
The maximal length of the exhaust hose is 150
cm. Do not use extensions or other exhaust
hoses; this can cause serious malfunctions.
To prevent overheating, the outlet of the device
must not be blocked.
If you have a tilt window instead of a sliding
window, purchase a window sealing kit to close
off your entire window airtight.
USAGE - Turning on and off
1. Put the plug in the socket. The devices peeps, which is normal. The display (figure 1, a) indicated the
current room temperature.
2. Push the button "power" (h). The device starts functioning in the last used mode. When you turn the
device on for the first time, it is in the cooling mode. The indication light above the button "mode" lights
up.
3. Set the desired direction of the air stream. Aim the air stream right ahead, or slightly downward by
manually setting the horizontal slats (6) in desired position. You can easily turn of move the device with
the sturdy castor wheels to direct the airstream into the room.
4. Push the button "power" again to turn the device off.
5. After use, pull the plug from the socket.
USAGE - Setting the mode
The device has three operating modes, with which you can ventilate, dehumidify, and cool the room.
Ventilating
1. Press the button "mode" (figure 1, g), until the indication light lights up at "fan". The device is now
functioning as ventilator.
2. Press the button "speed" (c) to change between low or high speed exhaust air. The indication light lights
up at "low" (low speed) or "high" (high speed).
Dehumidifying
1. Press the button "mode" (figure 1, g) once or multiple times, until the indication light lights up at "dehum".
The device switches to the lowest speed, and will now dehumidify the air.
ATTENTION:
When the internal water collection tray is full, the device stops functioning, and the indication light lights
up on the control panel at "water full". You have to empty the water collection tray before you can
continue using the device (see 'CLEANING AND MAINTENANCE – Water drainage').
If you often use the device to dehumidify the air, you can also use the continuous drainage (see
'CLEANING AND MAINTENANCE – Water drainage').
44
EN
2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis