Herunterladen Inhalt Inhalt Diese Seite drucken

EINHELL TC-AC 190 OF Set Originalbetriebsanleitung Seite 23

Koffer-kompressor
Vorschau ausblenden Andere Handbücher für TC-AC 190 OF Set:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
10. Possible causes of failure
Problem
The compressor
1. No supply voltage.
does not start.
2. Insu cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
The compressor
1. The non-return valve leaks.
starts but there is no
pressure.
2. The seals are damaged.
The compressor
1. The hose connections have a leak.
starts, pressure is
shown on the pres-
2. A quick-lock coupling has a leak.
sure gauge, but the
tools do not start.
GB
Cause
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5° C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
- 23 -
Solution

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

40.206.60

Inhaltsverzeichnis