INSTALLATION OF THE INSIDE UNIT

4
Put the unit on the floor or on his horizontal support,
-
It shouldn't be any obstacle in front of the ventilation grid to facilitate the air flow
-
-
The support or floor must be level and not transmit vibrations.
-
4.1

RE-CONNECTION OF THE FLEXIBLE

Pass the connecting flexible through the hole in the wall and re-connect the refrigerant fittings with the wrenches
and the electrical connecting wires to the outside unit. The reconnection can be done to any pipe.
Attention : open the ends of the flexible connection when you pass them through the wall in order to keep
the end clean for screwing again.
4.2

INSTALLING THE CONDENSING WATER FLUE

Screw the plastic bend 1 supplied with the unit
Slide the PVC tubing 2
Screw up the ring clamp 3
Connect the free end of the PVC tubing to a wastewater point or a retention tank ( mini content 25 litres).
Avoid "counter slopes " or « siphons »
1
2
3
If necessary seal the threads with Teflon