THE FUNCTION MAY BE TERMINATED (THE LIGHT LED
GOES OFF):
- by user command, pressing the airpool key;
- by user command, pressing the 0/I key;
- when the function expiration time is up (45
minutes);
- if, during operation, an insufficient level of water
is detected in the tub.
VARIATION OF % POWER
With the blower on, hold the airpool key down
for at least 0.5 to enter variation mode. By holding
the key down, the power percentage is increased/
decreased continuously, stopping respectively at
the minimum and at the maximum.
Release the key before the blower reaches maxi-
mum or minimum power to set blower operation
at the desired power percentage.
If you subsequently wish to change the power,
proceed as described above. You will continue to
increase or decrease the value based on the actions
taken in the previous step.
TWIN FUNCTION
(simultaneously activates whirlpool and
airpool functions)
Meaning of LED status
Phase
Twin Selection/Operation
WHEN THE TWIN KEY IS PRESSED:
- if the water level is acceptable, press the 0/I key
within 5 seconds (otherwise the Twin LED shuts
off ) so that the 0/I key LED comes on steady
green and the pump and the blower start;
- if water level in the tub is insufficient, the func-
tion will not start;
THE FUNCTION MAY BE TERMINATED (THE LIGHT LED
GOES OFF):
- if the water level is acceptable, press the 0/I key
within 5 seconds (otherwise the Twin LED shuts
off ) so that the 0/I key LED comes on steady
green and the pump and the blower start;
- if water level in the tub is insufficient, the func-
tion will not start;
32
TT0283660_05_PREMIUM_CMYK.indd 32
Downloaded from
www.Manualslib.com
led
status
Twin LED steady blue
manuals search engine

WHIRLPOOL FUNCTION

(activates the pump for the whirlpool,
nozzles on sides of tub)
Meaning of LED status
Phase
Selection/function whirlpool
WHEN THE WHIRLPOOL KEY IS PRESSED:
- if no functions are active (0/I LED with steady
red light), press the 0/I key within 5 seconds
(otherwise the Whirlpool LED shuts off ) so that
the 0/I key LED comes on steady green and the
pump starts;
- if there are functions active (0/I LED with steady
green light), the pump starts;
- if water level in the tub is insufficient, the pump
will not start;
- fill the tub up to a level which is 5 cm above the
nozzle;
THE FUNCTION MAY BE TERMINATED (THE LIGHT LED
GOES OFF):
- by user command, pressing the whirlpool key;
- by user command, pressing the 0/I key;
- when the function expiration time is up (45
minutes);
- if, during operation, an insufficient level of water
is detected in the tub;
VENTURI FUNCTION
(only with whirlpool function active -
activates the motorized valve)
Meaning of LED status
Phase
Function selection Venturi
Whirlpool operation
WHEN THE VENTURI TUBE KEY IS PRESSED:
- the amount of air in the whirlpool is cyclically
varied.
THE FUNCTION MAY BE TERMINATED (THE LIGHT
LED GOES OFF):
- when the whirlpool function ends;
- by pressing/releasing the Venturi tube key.
led
status
whirlpool LED steady
blue
led
status
Venturi LED steady blue
whirlpool LED on
steady blue
28/03/11 16.05