4. With a thin screwdriver, adjust the by-
pass screw position. If you change
from natural gas 20 mbar to liquid gas,
fully tighten the adjustment screw in. If
you change from liquid gas to natural
gas 20 mbar, undo the by-pass screw
approximately 1/4 of a turn.
1
Minimum adjustment screw
5. Make sure the flame does not go out
when you quickly turn the knob from
the maximum position to the minimum
position.
Oven injector replacement
1. Remove the bottom plate of the oven
cavity (A) to get access to the gas oven
burner (B).
B A
2. Release the two screws (C), which
keep the gas oven burner in position.
C
Downloaded from
www.Manualslib.com
1
manuals search engine
3. Carefully move the gas oven burner off
the injector support (D).
Slowly move it to the left side. Make
sure that the gas oven burner bush
stays on the burner mouthpiece. Do
not apply force to the wire of the spark
plug connector (E) and to the thermo-
couple conductor (F).
D
E
4. Release the gas burner injector (D) with
a 7 mm socket spanner and remove it.
Replace it with the necessary one (see
table „Gas Oven Burner Data").
5. Assemble the gas oven burner in oppo-
site sequence.
6. Replace the gas type sticker near the
gas supply ramp with the one related to
the new gas type (supplied with the in-
jector kit).
Warning! A primary air adjustment of
the gas oven burner is not necessary.
Minimum level adjustment of the gas
oven burner:
1. Disconnect the mains plug from the
mains socket.
2. Remove the gas oven control knob.
F