OPERATION

7 6
D
Buttons: A - ON/OFF; B - Timer; C - Humidity level; D - Fan speed
Switching the unit ON and OFF [A]
When the unit is plugged in, a buzzer will beep and
the display will show the room humidity.
Push the ON/OFF button once to start operation
at the default humidity level of 60% with low fan
speed, LED [2] and LED [6] will light.
Push the button again to switch the unit off.
Setting the Timer [B]
The timer switches the unit on and off automatically
within 24 hours. When the TIMER is set, the LED [3]
will light up.
Programming the timer for ON - when the
unit is OFF
When the unit is plugged in but not running, push
the TIMER button repeatedly to desired hour when
the unit will switch ON.
Programming the timer for OFF - when the
unit is ON
When the unit is running, push the TIMER button
repeatedly to desired hour when the unit will switch
OFF.
E
28
5
4
3
C
B
2
1
A

Cancelling the timer

In order to cancel the timer setting, push the TIMER
button to adjust the timer to 00, the LED [3] will
go off.
Setting the Humidity level [C]
The humidistat range for this unit is 40% to 80%.
Push the HUMIDITY button to set the desired humi-
dity level, (the humidity can be set in steps of 5%)
the display will show the circle as: 60, 65...80, 40,
45...60. LED [5] will light during the setting.
When the dehumidify function is operating, the LED
[2] will light.
If the room humidity is lower then the selected hu-
midity, the unit will stop dehumidify automatically,
the fan only circulates the air.
Setting the fan speed [D]
Push the FAN SPEED button the change the desired
fan speed, the low speed LED [6] and high speed
LED [7] will light accordingly.

Automatic defrosting

When this unit is running in a room temperature
between 5 °C to 12 °C, it will stop to defrost every
30 minutes.
When this unit is running in a room temperature
between 12 °C to 20 °C, it will stop to defrost
every 45 minutes.
1. Water tank full
2. Dehumidifying
3. Timer is set
4. Display
5. Setting humidity level
6. Low fan speed
7. High fan speed

Werbung