E. Factory Defined Programs: FTY PROG (0-6,8), USER
PROG (10-16,18)
F. Set Program Time:
1. Press <PRG>, Day of Week (1-7) will flash, press
< >/<
> to make Day of Week changes.
2. Press <PRG>, Program Nos. P (0-6,8,10-16,18) will
flash, press < >/<
> to make Program nos.
changes.
3. Press <
>/< > will select the Hour Bar for user
programs (10-16,18).
4. Press <
> to jump back to Normal Time Mode, or
auto return after 10 seconds.
G. Comfort and Economy Temperature Setting:
1. Hold <
>/< > for 1 sec will enter Comfort and
Economy Temperature Setting mode.
2. Press < >/< > to adjust different temperature.
3. Press <
> to jump back to Normal Time Mode, or
auto-return after 10 sec.
H. Manual Override Mode:
1. Press <
>/< > will enter the Manual Override mode,
with opposite state of
displayed.
2. Press <
(Defined Program)
auto-return after 10 sec.
(Defined Program)
3. Press < >/<
(Defined Program)
Manual Override mode.
(Defined Program)
4. Press <
(Defined Program)
(Whole Day
Override mode.
Comfort mode)
5. Next program of opposite state or next day will release
(Whole Day
Economy mode)
Manual Override mode.
(Defrost Program)
I. Comfort and Economy Hold Timer:
1. Hold <
enter the Comfort Hold Timer
2. Press < >/< > to adjust Hours of Temperature in
hold.
3. Press <
return after 10 sec.
4. Press < >/< > to adjust different temperature of the
Comfort Hold Timer in the Normal Time mode with
Hold Timer set.
5. Press < > will release Comfort Hold Timer.
6. Hold < > for 1 sec & press <
Economy Hold Timer with flashing
is same as point 2-4 while press <
Economy Hold Timer.
J. Specification:
1. Temperature measurement: 0.0 - 39.5 °C (0.5 C
/step)
2. Accuracy:
<
>/< >
mode and with
> jump back to Normal Time Mode, or
> to adjust different temperature to
>/< > of opposite state will release Manual
> for 1 second and press <
> or < > will
with flashing.
> jump back to Normal Time Mode, or auto
> or < > will enter the
and other step
> will release
± 0.5 °C
3. Temperature control range: 5.0 - 35.0 °C (0.5°C /step)
4. Temperature detection:
per 10 sec.
5. Switching:
24...250VAC 50/60Hz
8A max Resistive
6. Terminals:
2.5 mm
7. Electronic control:
Type 2.B action
8. Battery:
2 x 1.5V AA alkaline
9. Operating temperature:
-10 - 50 °C
10. Storage temperature:
-20 - 60 °C
11. Operating humidity:
5-90% non-condensing
2
cable