Installing and Operating Instructions
12.1 PROBE CONNECTION
The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid
infiltration. It is recommended to place the thermostat probe away from air streams to correctly
measure the average room temperature. Place the defrost termination probe among the evaporator
fins in the coldest place, where most ice is formed, far from heaters or from the warmest place during
defrost, to prevent premature defrost termination.
13. HOW TO USE THE HOT KEY
13.1 HOW TO PROGRAM A HOT KEY FROM THE INSTRUMENT (UPLOAD)
1.
Program one controller with the front keypad.
2.
When the controller is ON, insert the "Hot key" and push o key; the "uPL" message
appears followed a by flashing "End"
3.
Push "SET" key and the End will stop flashing.
4.
Turn OFF the instrument remove the "Hot Key", then turn it ON again.
NOTE: the "Err" message is displayed for failed programming. In this case push again o key if you
want to restart the upload again or remove the "Hot key" to abort the operation.
13.2 HOW TO PROGRAM AN INSTRUMENT USING A HOT KEY
(DOWNLOAD)
1.
Turn OFF the instrument.
2.
Insert a programmed "Hot Key" into the 5 PIN receptacle and then turn the Controller ON.
3.
Automatically the parameter list of the "Hot Key" is downloaded into the Controller memory,
the "doL" message is blinking followed a by flashing "End".
4.
After 10 seconds the instrument will restart working with the new parameters.
5.
Remove the "Hot Key"..
NOTE the message "Err" is displayed for failed programming. In this case turn the unit off and then
on if you want to restart the download again or remove the "Hot key" to abort the operation.
14. ALARM SIGNALS
Message
Cause
"P1"
Room probe failure
"P2"
Evaporator probe failure
"P3"
Third probe failure
"P4"
Fourth probe failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"HA2"
Condenser high temperature
"LA2"
Condenser low temperature
"dA"
Door open
"EA"
External alarm
"CA"
Serious external alarm (i1F=bAL) All outputs OFF.
"CA"
Pressure switch alarm (i1F=PAL) All outputs OFF
"rtc"
Real time clock alarm
rtF
Real time clock board failure
14.1 ALARM RECOVERY
Probe alarms P1", "P2", "P3" and "P4" start some seconds after the fault in the related probe; they
automatically stop some seconds after the probe restarts normal operation. Check connections
before replacing the probe.
Temperature alarms "HA", "LA" "HA2" and "LA2" automatically stop as soon as the temperature
returns to normal values.
Alarms "EA" and "CA" (with i1F=bAL) recover as soon as the digital input is disabled.
Alarm "CA" (with i1F=PAL) recovers only by switching off and on the instrument.
14.2 OTHER MESSAGES
Pon
Keyboard unlocked.
PoF
Keyboard locked
noP
In programming mode: none parameter is present in Pr1
On the display or in dP2, dP3, dP4: the selected probe is nor enabled
15. TECHNICAL DATA
Housing: self extinguishing ABS.
Case: XR70CX frontal 32x74 mm; depth 60mm;
Mounting: XR70CX panel mounting in a 71x29mm panel cut-out
Protection: IP20; Frontal protection: XR70CX IP65
Connections: Screw terminal block ≤ 2,5 mm
Power supply: according to the model: 12Vac/dc, ±10%; 24Vac/dc, ±10%;
50/60Hz, 110Vac ±10%, 50/60Hz
Power absorption: 3VA max
Display: 3 digits, red LED, 14,2 mm high; Inputs: Up to 4 NTC or PTC probes.
Digital input: free voltage contact
Relay outputs: compressor SPST 8(3) A, 250Vac; SPST 16(6)A 250Vac
defrost: SPDT 8(3) A, 250Vac or SPST 16(6)A 250Vac
fan: SPST 5A, 250Vac or SPST 16(6)A 250Vac
aux: SPDT 8(3) A, 250Vac or SPST 16(6)A 250Vac
Data storing: on the non-volatile memory (EEPROM).
Internal clock back-up: 24 hours
Kind of action: 1B; Pollution grade: 2;Software class: A.; Rated
impulsive voltage: 2500V; Overvoltage Category: II Operating
temperature: 0÷60 °C; Storage temperature: -25÷60 °C. Relative
humidity: 20÷85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C (-40÷230°F);
PTC probe: -50÷150°C (-58÷302°F)
1592020570 XR70CX RTC GB r1.0 28.05.2008
Outputs
Compressor output acc. to par. "Con" and "COF"
Defrost end is timed
Outputs unchanged
Outputs unchanged
Outputs unchanged.
Outputs unchanged.
It depends on the "Ac2" parameter
It depends on the "bLL" parameter
Compressor and fans restarts
Output unchanged.
Alarm output ON; Other outputs unchanged;
Defrosts according to par. "IdF" Set real time clock
has to be set
Alarm output ON; Other outputs unchanged;
Defrosts according to par. "IdF" Contact the
service
2
wiring.
230Vac ±10%,
Resolution: 0,1 °C or 1°C or 1 °F (selectable); Accuracy (ambient temp. 25°C): ±0,7 °C ±1 digit
16. CONNECTIONS
The X-REP output excludes the TTL output.. It's present in the following codes:
XR70CX- xx2xx, XR70CX –xx3xx;
16.1 XR70CX – 8A OR 16A COMP. RELAY - 120VAC OR 230VAC
16.2 XR70CX –4 X 16A - 12VAC/DC
17. DEFAULT SETTING VALUES
Labe
Name
Set Set point
rtc Real time clock menu
Hy Differential
LS Minimum set point
US Maximum set point
Ot Thermostat probe calibration
P2P Evaporator probe presence
OE Evaporator probe calibration
P3P Third probe presence
O3 Third probe calibration
P4P Fourth probe presence
O4 Fourth probe calibration
OdS Outputs delay at start up
AC
Anti-short cycle delay
rtr
P1-P2 percentage for regulation
CCt Continuos cycle duration
CCS Set point for continuous cycle
COn Compressor ON time with faulty probe
COF Compressor OFF time with faulty probe 0 ÷ 255 min
CF Temperature measurement unit
rES Resolution
Lod Probe displayed
2
rEd
X-REP display
dLy Display temperature delay
dtr P1-P2 percentage for disply
EdF Defrost mode
tdF Defrost type
dFP Probe selection for defrost termination
dtE Defrost termination temperature
IdF Interval between defrost cycles
MdF (Maximum) length for defrost
dSd Start defrost delay
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPo
First defrost after startup
dAF Defrost delay after fast freezing
Fnc Fan operating mode
Fnd Fan delay after defrost
Fct Differential of temperature for forced
activation of fans
FSt Fan stop temperature
Fon Fan on time with compressor off
FoF Fan off time with compressor off
FAP Probe selection for fan management
XR70CX
1592020570
NOTE: The
compressor relay is
8(3)A or 16(6)A
according to the
model.
24Vac supply:
connect to the
terminals 5 and 6.
Range
°C/°F
LS÷US
-5.0
-
-
0,1÷25.5°C/ 1÷ 255°F
2.0
-50°C÷SET/-58°F÷SET
-50.0
SET÷110°C/ SET ÷ 230°F
110
0.0
-12÷12°C /-120÷120°F
n=not present; Y=pres.
Y
-12÷12°C /-120÷120°F
0.0
n=not present; Y=pres.
n
0
-12÷12°C /-120÷120°F
n=not present; Y=pres.
n
-12÷12°C /-120÷120°F
0
0÷255 min
0
1
0 ÷ 50 min
0 ÷ 100 (100=P1 , 0=P2)
100
0.0÷24.0h
0.0
(-55.0÷150,0°C) (-67÷302°F)
-5
0 ÷ 255 min
15
30
°C
°C ÷ °F
dE
in=integer; dE= dec.point
P1;P2
P1
P1 - P2 - P3 - P4 - SEt - dtr
P1
0 ÷ 20.0 min (10 sec.)
0
1 ÷ 99
50
rtc - in
rtc
EL=el. heater; in= hot gas
EL
nP; P1; P2; P3; P4
P2
-50 ÷ 50 °C
8
1 ÷ 120 ore
6
30
0 ÷ 255 min
0÷99min
0
rt, it, SEt, DEF
it
0 ÷ 255 min
30
0÷120 min
0
n=after IdF; y=immed.
n
0 ÷ 23h e 50'
0.0
C-n, o-n, C-y, o-Y
o-n
0÷255min
10
0÷50°C
10
-50÷50°C/-58÷122°F
2
0÷15 (min.)
0
0÷15 (min.)
0
nP; P1; P2; P3; P4
P2
Level
- - -
Pr1
Pr1
Pr2
Pr2
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr2
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr2
Pr1
Pr2
Pr2
Pr2
4/5
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xw01000 h01-serie

Inhaltsverzeichnis