Assembly
1. Flush through the supply pipes.
2. Mount the ball S - unions.
Hot water connection left hand, cold water
connection on the right hand side.
3. Fasten the mixer using ball union nuts, align and
tighten it. The ball S - unions enable inaccuracies
in the wall installation to be compensated for,
whether in the horizontal direction, in the vertical
direction or in the parallel orientation.
4. Screw the escutcheons down the wall.
Large differences in pressure between the hot and cold
water supply should be balanced.
Adjustment
Correction is necessary if the temperature measured at
the take off point differs from the temperature set on the
scale. To adjust please see page 15.

Operation

The mixer is operated by turning the handle on the left
hand side. The green knob limits the rate of flow to
approx. 10 l/min. If a higher water consumtion is
required press the ECOSTOP button and turn handle
further.
The temperature is selected by turning the graduated
handle on the right side.

Temperature limitation

The temperature is limited by the safety check to 38° C.
If a higher temperature is required, it is possible to
override the safety stop by depressing the safety button.
To garantee a smooth running of the thermoelent, it is
necessary from time to time to turn the thermostat from
total hot to total cold.
6
English
The mixer is equipped with non return valves.
Attention!
The non return valves must be checked once a year.
Using the thermostatic mixer in conjunction
with combination boilers.
When using the thermostatic mixer with combination
boilers, the Ecostop ring "8" has to be removed.
If fitting a hand shower remove the water limiter from
the shower. (Please see page 16)
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 3 bars:
anti-pollution function

Spare parts

1 thermoelement
2 shut off unit
3 knob for thermoelement
4 knob for shut off unit
5 non return valve DW 16
6 ball s-unions
7 safety set for temperature control 50110000033
8 safety set for flow control
XX
= Colors
01 chrome
07 stainless steel-finish
17 aluminium-finish
max. 10 bars
1 - 5 bars
16 bars
max. 80° C
65° C
20 l/min
50110000006
50110000028
50110XX0029
50110XX0030
50110000031
50110000032
50110000034