Herunterladen Diese Seite drucken

Renkforce 1221087 Bedienungsanleitung Seite 2

Tisch-mikrofon

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating instructions
Table microphone
Item no. 1221087
Intended use
This microphone is designed to convert acoustic signals (sound waves) into electrical signals.
It can be used for announcements, interviews, press conferences or lecterns. The flexible
gooseneck allows the microphone to be adjusted for different speaking positions and speakers.
The low-level audio output signal must only be connected to suitable microphone inputs on audio
devices.
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bathrooms,
must be avoided under all circumstances.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you
use the product for purposes other than those described above, the product may be damaged. In
addition, improper use can cause hazards such as short circuiting, fire, electric shock etc. Read
the instructions carefully and keep them. Make this product available to third parties only together
with its operating instructions.
This product complies with the statutory national and European requirements. All company names
and product names are trademarks of their respective owners. All rights reserved.
Delivery content
• Table microphone
• Operating instructions
Safety instructions
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information on proper
handling in this manual, we assume no liability for any resulting personal injury or
damage to property. Such cases will invalidate the warranty/guarantee.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed if
the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
• Consult an expert when in doubt about operation, safety or connection of the device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.
Operation
The product must only be connected to suitable microphone inputs in order to
avoid distortions or mismatches that could cause damage to the microphone or the
connected audio device. Pay attention to the connection values in the "Technical
data".
Never direct the microphone at the sound outlet of loudspeakers, as this can result in
feedback which may damage the loudspeakers and the connected amplifier.
a) Connection
1. Ensure that you place the product in a secure position.
2. Turn off the audio device to which the microphone will be connected.
3. Turn the microphone off using the on/off toggle switch on the base (move it to the middle
position) (OFF).
4. Insert the 6.3 mm jack plug on the microphone cable into the microphone connection on your
audio device.
b) Switch positions
Announcement ON
Microphone
OFF
Speaking
ON
c) Using the microphone
1. Turn the sensitivity of your audio device to zero using the corresponding input level control
(refer to the operating instructions of the audio device you are using).
2. Turn on your audio device with the connected sound source (loudspeakers).
3. Turn on the microphone using the on/off toggle switch on the base (move downwards) (ON).
4. Test the microphone by speaking a few words (e.g. counting whole numbers) whilst slowly
moving the input level control on the audio device upwards until the desired output volume
is reached.
5. To make short announcements, move the on/off toggle switch on the base upwards and hold
it in this position while you are speaking. Release the switch when the announcement is
complete. The microphone is now turned off.
Maintenance and cleaning
• The product does not require maintenance except for occasional cleaning.
• Under no circumstances should you service any of the components in the interior of the product,
therefore never open it.
• Before cleaning, remove the 6.3 mm jack plug from the connected audio device.
• For cleaning, use a soft, anti-static and lint-free cloth. Dust can be easily removed using a soft
and clean long-haired brush and a vacuum cleaner.
• Do not use abrasive or chemical cleaning agents.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household
waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.
Technical data
Frequency response ....................................100 Hz - 18000 Hz
Sensitivity ......................................................-76 dB
Impedance ....................................................600 Ω +30% (at 1kHz)
Directivity ......................................................Cardioid
Connection ....................................................6.3 mm jack plug
Cable length ..................................................1.8 m
Operating conditions ...................................-5 to +45 °C, <85 % RH
Storage conditions.......................................-20 to +60 °C, <95 % RH
Dimensions (L x W x H) ...............................158 x 118 x 354 mm
Weight ............................................................1.18 kg
Frequency response
Directivity
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.
V1_0914_02-DS