Herunterladen Diese Seite drucken

VOSS.farming BA-1260 Bedienungsanweisung Seite 3

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Specific Operating Instructions
2
1
4
3
5
The unit must, as a rule, be installed vertically with the connections at the bottom and, if possible, protected against rain,
see above picture, left side. In case of wall mounting, it must be mounted against a fireproof wall. For outdoor installation,
a zinc-plated metal casing can be used. This accessory (part No. 43640) protects the unit and also accommodates the
accumulator.
b.) Functional description of the unit
Put unit into service WITHOUT fence and earthing. When connecting the 12V accumulator, be sure to observe the
correct polarities (red + and black -). If the fence light (1) flashes green, the unit is ready for use. If in addition the
accumulator light (2) flashes red, check the 12V accumulator for correct voltage. If the fence light (1) does not flash,
check the polarity of the 12V connecting cable on the accumulator or have the unit checked by a technician. When
operating the unit with solar module or mains adapter, first remove the protective cover (4).
Switch positions:
c.) Functional description with connected fence system ( fence + earth )
Accumulator
Fence light
light (2)
(1) flashes
flashes red
green
1
NO
2
NO
YES
3
YES
4
YES
5
6
NO
If the fence light (1) flashes faster than approx. once per second, the unit must be disconnected at once and checked by
a technician before it can be used again.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
-
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
Accessories/Tips:
The power source consists of wet-cell batteries: 12V, 50 Ah up to 12V, 120 Ah.
For maintenance-free operation, we recommend the use of a solar system.
With a mains adapter (with galvanic isolation), Item No.:44228, 230V operation is also possible.
Ensure a good grounding of the devices, with at least 3 ground rods, Item No.:44219 (Item No.:44375 for mobile use).
6
Normal operation with 12V – wet accumulator;
alternatively, the appliance can be operated with a mains
adapter!
ON/ OFF
Audible
clicks
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
8
This energizer shall not be used 
as an animal trainer  
(inside a barn). 
7
Output voltage
> 3500 V = minimum requirement
< 3500 V; see fault finding in the enclosed
instruction manual (Figure 2, p.5)!
> 3500 V = minimum requirement
and:
< 3500 V; see fault finding in the enclosed
instruction manual (Figure 2, p.5)!
No pulses, deep charge protection activated
See b.) Functional description of the appliance, without fence and earth
3
SIGMA 6
1 Fence voltage
Indicator light
12V-ACCUMULATOR
2
indicator light
3 Switch
Socket for Solar
4
+ protection cover
12V / 230V connection
5
cable
6 Earth connection
7 Fence connection
8 Fastening holes
12V accumulator
OK ( >12,2V)
OK (>12,2V)
Charge or replace as
soon as possible
Charge or replace as
and:
soon as possible
Charge or replace at
once